XC822/824
Electrical Parameters
3.2.2 Supply Threshold Characteristics
Table 9 provides the characteristics of the supply threshold in the XC822/824.
5.0V
VDDP
VDDPSRR
VDDPPW/VDDPBOPD
VDDPBOA
2.5V
VDDC
VDDCSRR
VDDCPW
VDDCBOA
VDDCBOPD
VDDCRDR
Figure 9 Supply Threshold Parameters
Table 9
Supply Threshold Parameters (Operating Conditions apply)
Parameters
Symbol
Limit Values Unit
Min. Typ. Max.
VDDP prewarning voltage1)2)
VDDP brownout voltage in active mode3)2)
VDDPPW CC 3.0 3.6 4.5 V
VDDPBOA CC 2.65 2.75 2.87 V
VDDP brownout voltage in power down
mode2)3)
VDDPBOPD CC 3.0 3.6 4.5 V
VDDP system reset release voltage2)4)
VDDPSRR CC 2.7 2.8
VDDC prewarning voltage2)5)
VDDCPW CC 2.3 2.4
VDDC brownout voltage in active mode2)
VDDCBOA CC 2.25 2.3
VDDC brownout voltage in power down mode2) VDDCBOPD CC 1.35 1.5
VDDC system reset release voltage2)4)
VDDCSRR CC 2.28 2.3
2.92 V
2.48 V
2.42 V
1.95 V
2.47 V
RAM data retention voltage
VDDCRDR CC 1.1 –
V
1) Detection is enabled via SDCON register in active mode. It is automatically disabled in power down mode.
Detection should be disabled for VDDP less than maximum of VDDPPW.
2) This parameter has a hysteresis of 50 mV.
3) Detection is enabled via SDCON register. Detection must be disabled for application with VDDP less than the
specified values.
4) VDDPSRR and VDDCSRR must be met before the system reset is released.
5) Detection is enabled via SDCON register in active mode. It is automatically disabled in power down mode.
Data Sheet