XC858CA
Electrical Parameters
4.1.3 Operating Conditions
The following operating conditions must not be exceeded in order to ensure correct
operation of the XC858. All parameters mentioned in the following table refer to these
operating conditions, unless otherwise noted.
Table 33 Operating Condition Parameters
Parameter
Symbol
Limit Values
min.
max.
Unit Notes/
Conditions
Digital power supply voltage VDDP
4.5
5.5
V 5V Device
Digital ground voltage
CPU Clock Frequency1)
VSS
0
fCCLK
V
24
MHz
Ambient temperature
TA
-40
85
°C SAF-XC858
1) fCCLK is the input frequency to the XC800 core. Please refer to Figure 22 for detailed description.
Data Sheet
94
V1.0, 2010-03