SDA 2526-5
Figure 2
Timing Conditions for the I2C Bus (high-speed mode)
Parameter
Symbol
Limit Values
Unit
min.
max.
Minimum time the bus must be free
before a new transmission can start
Start condition hold time
Clock low period
Clock high period
Start condition set-up time,
only valid for repeated start code
Data set-up time
Rise time of both the SDA- and SCL-line
Fall time of both the SDA- and SCL-line
Stop condition set-up time
Hold time data
tBUF
4.7
µs
tHD;STA 4.0
µs
tLOW
4.7
µs
tHIGH
4.0
µs
tSU;STA 4.7
µs
tSU;DAT 250
ns
tR
1
µs
tF
300
ns
tSU;STO 4.7
µs
tHD;DAT 0*)
* Note that a transmitter must internally provide at least a hold time to bridge the undefined region (max. 300 ns)
of the falling edge of SCL.
Semiconductor Group