SLB 0587
Control Modes of Operation
Mode
A (Pin 2 at V SS)
B (Pin 2 open)
C (Pin 2 at V DD)
Period of Touching the Sensor/Extension
Short (60 to 400 ms)
Long (more than 400 ms)
Pre-Touch
Status
Post-Touch
Status
Pre-Touch
Status
Post-Touch
Status
OFF
Max.
Intermediate
Softstart to Max.
OFF
OFF
OFF
Max./Intermediate
Repeated dimming
Starts varying at min.
Starts varying at
pre-touch brightness
Same dimming
direction
OFF
Max.
Intermediate
OFF
Max.
Intermediate
Softstart to
stored brightness
from last turn-OFF
OFF
OFF
OFF
Max./Intermediate
Repeated dimming
Softstart to Max.
OFF
OFF
OFF
Max./Intermediate
Repeated dimming
Softstart to stored
brightness
and varying
Starts varying at
pre-touch brightness
Reversed dimming
direction
Starts varying at min.
Starts varying at
pre-touch brightness
Reversed dimming
direction
Figure 3
Control Behaviour of the 3 Operating Modes