SPLC783A
5.2.6. Function set
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
Display data RAM can be read or written after this setting.
Code
0 0 0 0 1 DL N F X X
In one-line display (N = 0),
X: Do not care (0 or 1)
(aaaaaaa)2: (00)16 - (4F)16.
DL: It sets interface data length.
DL = 1: Data transferred with 8-bit length (DB7 - 0).
In two-line display (N = 1),
DL = 0: Data transferred with 4-bit length (DB7 - 4).
It requires two times to accomplish data transferring.
(aaaaaaa)2: (00)16 - (27)16 for the first line,
N: It sets the number of the display line.
N = 0: One-line display.
N = 1: Two-line display.
l F: It sets the character font.
tia ly F = 0: 5 x 8 dots character font.
F = 1: 5 x 10 dots character font.
n n N F No. of Display Lines Character Font Duty Factor
e O 0 0
1
5 x 8 dots
1/8
fid e 0 1
1
5 x 10 dots
1 / 11
s 1 X
2
5 x 8 dots
1 / 16
n It cannot display two lines with 5 x 10 dots character font.
o U 5.2.7. Set character generator RAM address
s C ER Code
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
0001aaaaaa
(aaaaaaa)2: (40)16 - (67)16 for the second line.
5.2.9. Read busy flag and address
Code
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
0 1 BF a a a a a a a
When BF = 1, it indicates the system is busy now and it will not
accept any instruction until not busy (BF = 0). At the same time,
the content of Address Counter (aaaaaaa)2 is read.
5.2.10. Write data to character generator RAM or
display data RAM
Code
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
10dddddddd
plu IN It sets Character Generator RAM Address (aaaaaa)2 to the
n M Address Counter.
Su RT Character Generator RAM data can be read or written after this
setting.
PA 5.2.8. Set display data RAM address
For Code
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
001aaaaaaa
It writes data (dddddddd)2 to character generator RAM or display
data RAM.
5.2.11. Read data from character generator RAM or
display data RAM
Code
RS R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
11dddddddd
It reads data (dddddddd)2 from character generator RAM or
display data RAM.
It sets Display Data RAM Address (aaaaaaa)2 to the Address
Counter.
To read data correctly, do the following:
1). The address of the Character Generator RAM or Display Data
RAM or shift the cursor instruction.
2). The “ Read ” instruction.
© Sunplus Technology Co., Ltd.