datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

TC74AC390F 查看數據表(PDF) - Toshiba

零件编号
产品描述 (功能)
比赛名单
TC74AC390F Datasheet PDF : 10 Pages
1 2 3 4 5 6 7 8 9 10
TC74AC390P/F/FN
AC Characteristics (CL = 50 pF, RL = 500 Ω, input: tr = tf = 3 ns)
Characteristics
Propagation delay
time
( CKA -QA)
Propagation delay
time
( CKA -QC)
Propagation delay
time
( CKB -QB, QD)
Propagation delay
time
( CKB -QC)
Propagation delay
time
(CLR-Qn)
Maximum clock
frequency
( CKA )
Maximum clock
frequency
( CKB )
Input capacitance
Power dissipation
capacitance
Symbol
tpLH
tpHL
Test Condition
VCC (V)
3.3 ± 0.3
5.0 ± 0.5
Ta = 25°C
Min Typ. Max
8.2 14.0
5.5
8.4
tpLH
3.3 ± 0.3 17.0 30.0
QA connected to CKB
tpHL
5.0 ± 0.5 10.5 17.5
tpLH
3.3 ± 0.3
8.8 14.9
tpHL
5.0 ± 0.5
6.0
9.4
tpLH
3.3 ± 0.3 11.0 18.8
tpHL
5.0 ± 0.5
7.1 11.3
3.3 ± 0.3
7.7 12.5
tpHL
5.0 ± 0.5
5.7
8.5
3.3 ± 0.3 60
120
fmax
5.0 ± 0.5 100 180
fmax
CIN
CPD
(Note)
3.3 ± 0.3 45
90
5.0 ± 0.5 90
140
5
10
40
Ta = −40 to
85°C
Unit
Min Max
1.0 16.0
ns
1.0 9.6
1.0 34.0
ns
1.0 20.0
1.0 17.0
ns
1.0 10.7
1.0 21.5
ns
1.0 12.8
1.0 14.3
ns
1.0 9.7
60
MHz
100
45
MHz
90
10
pF
pF
Note:
CPD is defined as the value of the internal equivalent capacitance which is calculated from the operating
current consumption without load.
Average operating current can be obtained by the equation:
ICC (opr) = CPDVCCfIN + ICC/2 (per counter)
6
2007-10-01

Share Link: 