TORX111
2. Recommended Operating Conditions
Characteristics
Supply Voltage
Load Impedance
Load Capacitor
(Note 3)
(Note 3)
Note 3: Load of analogue output.
Symbol
VCC
Min Typ. Max Unit
4.75 5.0 5.25
V
10
K
10
pF
3. Electrical and Optical Characteristics (Ta = 25°C, VCC = 5 V)
Characteristics
Symbol
Test Condition
Min Typ. Max Unit
Data Rate
Transmission Distance
Pulse Width Distortion
Maximum Receivable
Power
Minimum Receivable
Power
Current Consumption
Analogue Output Voltage
High Level Output Voltage
Low Level Output Voltage
(Note 6)
(Note 7)
(Note 7)
NRZ code
(Note 4) DC
APF (Note 5) with TOTX111
0.2
Pulse width 165 ns
tw
Pulse cycle 330 ns
CL = 10 pF
55
PMAX
APF (Note 5), 6 Mb / s NRZ code
4.5
6 Mb / s
10
m
55
ns
dBm
PMIN
APF (Note 5), 6 Mb / s NRZ code
22 dBm
ICC
VA
VOH
VOL
PIN = 4.5 to 22 dBm
PIN = −∞ dBm
12
20
mA
2.3
2.8
V
1.6
V
4.6
V
0.4
V
Note 4: When optical input is on, output level is high. Optical input is off, output is low.
Note 5: All Plastic Fiber (980 µm core, 1000 µm cladding).
Note 6: Between input of TOTX111 and digital output of TORX111.
Note 7: BER 109. Peak value.
4. Mechanical Characteristics (Ta = 25°C)
Characteristics
Symbol
Test Condition
Min Typ. Max Unit
Fiber Insert Force
Fiber Clamping Force
Ring Unclamping Force
FFI
Using TOFC100, First value
(Note 8)
FFC
Using TOFC100, First value
(Note 9)
FRC
Using TOFC100, First value
6
19.6
N
19.6 35
N
10 19.6
N
Note 8: The optical fiber is disconnected when it is pulled with this load in the axial direction.
Note 9: This is the load required for the clamp release ring to release the optical fiber clamp.
When disconnecting the optical fiber, hold in the clamp release ring.