datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MAX2362ECM 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
比赛名单
MAX2362ECM
MaximIC
Maxim Integrated MaximIC
MAX2362ECM Datasheet PDF : 24 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Complete Dual-Band
Quadrature Transmitters
ELECTRICAL CHARACTERISTICS (continued)
(MAX2360/62/64 evaluation kit, 50system, operating modes as defined in Table 6, input voltage at I and Q = 200mVRMS differen-
tial, common mode = VCC/2, 300kHz quadrature CW tones, RF and IF synthesizers locked with passive lead-lag second-order loop
filter, REF = 200mVp-p at 19.68MHz, VCC = SHDN = IDLE = CS = TXGATE = 2.75V, VBAT = 2.75V, IF output load = 400, LOH, LOL
input power = -7dBm, fLOL = 966MHz, fLOH = 1750MHz, IFINH = 125mVRMS at 130MHz, IS-95 CDMA modulation fRFH0 = fRFH1 =
1880MHz, fRFL = 836MHz, TA = +25°C, unless otherwise noted.)
PARAMETER
CONDITIONS
MIN TYP MAX UNITS
IF_PLL
Reference Frequency
5
30
MHz
Frequency Reference Signal Level
0.1
0.6 Vp-p
IF Main Divide Ratio
IF Reference Divider Ratio
VCO Operating Range
IF LO Output Power
Charge-Pump Source/Sink Current
Turbolock Boost Current
VCO = low
VCO = high
BUF_EN = 1
ICP = 00 (Note 6)
ICP = 01 (Note 6)
ICP = 10 (Note 6)
ICP = 11 (Note 6)
(Notes 5, 6)
256
16384
2
2048
240–470
240–600
-6
115
175
230
145
235
315
235
350
470
300
465
625
265
450
615
MHz
dBm
µA
µA
Charge-Pump Source/Sink Matching
Locked, all values of ICP, over specified
compliance range (Note 6)
5
%
Charge-Pump High-Z Leakage
RF_PLL
RF Main Divide Ratio
RF Reference Divide Ratio
Over specified compliance range
4096
2
10
nA
262144
8192
Maximum Phase-Detector Comparison
Frequency
10
MHz
Charge-Pump Source/Sink Current
RCP = 00 (Note 6)
RCP = 01 (Note 6)
RCP = 10 (Note 6)
100
165
225
135
230
310
µA
210
340
460
Turbolock Boost Current
RCP = 11 (Note 6)
(Notes 5, 6)
270
450
630
245
435
630
µA
Charge-Pump Source/Sink Matching
Locked, all values of RCP, over specified
compliance range (Note 6)
5
%
Charge-Pump High-Z Leakage
RFPLL Input Sensitivity
Over specified compliance range
10
nA
160
mVp-p
Note 1: See Table 6 for register settings.
Note 2: ACPR is met over the specified VCM range.
Note 3: VCM must be supplied by the I/Q baseband source with ±6µA capability.
Note 4: Guaranteed by design and characterization.
Note 5: When enabled, turbolock is active during acquisition and injects boost current in addition to the normal charge-pump current.
Note 6: >25°C guaranteed by production test, <25°C guaranteed by design and characterization.
4 _______________________________________________________________________________________