Operating Currents (TA = 0 to 70°C, VCC = 3.3V ± 0.3V)
(Recommended Operating Conditions unless otherwise noted)
Symbol Parameter & Test Condition
-7
ICC1 Operating Current
1 bank operation
150
tRC = tRCMIN., tRC = tCKMIN.
Active-precharge command
cycling,
without Burst Operation
ICC2P Precharge Standby Current
tCK = min.
2
in Power Down Mode
ICC2PS CS =VIH, CKEVIL(max)
tCK = Infinity
1
ICC2N Precharge Standby Current
tCK = min.
45
in Non-Power Down Mode
ICC2NS CS =VIH, CKEVIL(max)
tCK = Infinity
5
V54C365404VD(L)
Max.
-75 -8PC
-8
Unit Note
140
130
130
mA
7
2
2
2
mA
7
1
1
1
mA
7
40
35
35
mA
5
5
5
mA
ICC3
ICC3P
No Operating Current
tCK = min, CS = VIH(min)
bank ; active state ( 4 banks)
CKE VIH(MIN.)
CKE VIL(MAX.)
(Power down mode)
55
50
45
45
mA
8
8
8
8
mA
ICC4
Burst Operating Current
tCK = min
Read/Write command cycling
120
120
110
110
mA 7,8
ICC5
Auto Refresh Current
tCK = min
Auto Refresh command cycling
150
140
130
130
mA
7
ICC6
Self Refresh Current
Self Refresh Mode, CKE=<0.2V
L-version
1
1
1
1
mA
500
500
500
500
µA
Notes:
7. These parameters depend on the cycle rate and these values are measured by the cycle rate under the minimum value of tCK and
tRC. Input signals are changed one time during tCK.
8. These parameter depend on output loading. Specified values are obtained with output open.
V54C365404VD(L) Rev. 0.9 September 2001
11

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]