datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

W742C814 查看數據表(PDF) - Winbond

零件编号
产品描述 (功能)
比赛名单
W742C814
Winbond
Winbond Winbond
W742C814 Datasheet PDF : 46 Pages
First Prev 21 22 23 24 25 26 27 28 29 30 Next Last
W742C814
SEF.0 = 1
SEF.1 = 1
SEF.2 = 1
SEF.3 = 1
Device will exit stop mode when falling edge signal is applied to pin RC.0
Device will exit stop mode when falling edge signal is applied to pin RC.1
Device will exit stop mode when falling edge signal is applied to pin RC.2
Device will exit stop mode when falling edge signal is applied to pin RC.3
6.14 Hold Mode Operation
In hold mode, all operations of the µC cease, except for the operation of the oscillator, Timer, Divider,
LCD driver, DTMF generator and MFP generator. The µC enters hold mode when the HOLD
instruction is executed. The hold mode can be released in one of five ways: by the action of timer 0,
timer 1, divider 0, divider 1, the RC port. Before the device enters the hold mode, the HEF, PEF, and
IEF flags must be set to define the hold mode release conditions. For more details, refer to the
instruction-set table and the following flow chart.
Divider 0, Divider 1, Timer
0, Timer 1, Signal Change
at RC Port
Yes
Interrupt
Enable?
Yes
IEF
Flag Set?
Yes
No
No
In
No
HOLD
Mode?
No
Interrupt
Enable?
Yes
IEF
No
Flag Set?
Yes
Reset EVF Flag
Execute
Interrupt Service Routine
(Note)
HEF
Flag Set?
Reset EVF Flag
Execute
Interrupt Service Routine
No
Yes
(Note)
Disable interrupt
Disable interrupt
HOLD
PC <- (PC+1)
Note: The bit of EVF corresponding to the interrupt signal will be reset.
Figure 6-9 Hold Mode and Interrupt Operation Flow Chart
- 21 -
Publication Release Date: February 12, 2003
Revision A2

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]