HSP48212
AC Electrical Specifications (Continued)
40MHz
PARAMETER
SYMBOL
MIN
MAX
UNITS
MIX Data Setup Time to CLK High
t MS
10
-
ns
MIX Data Hold Time From CLK High
t MH
0
-
ns
Control Data Setup Time to CLK High
t CS
10
-
ns
Control Data Hold Time From CLK High
t CH
0
-
ns
DEL Setup to LD High
t DLS
12
-
ns
DEL Hold from LD High
t DLH
0
-
ns
CLK to Output Data Delay
t OUT
-
13
ns
Output Enable Time
t OE
-
13
ns
Output Disable Time
t OD
-
13
ns, Note 6
Output Rise/Fall Time
t RF
-
5
ns. Note 6
NOTES:
5. AC tests performed with CL = 40pF, IOL = 2mA, and IOH = -400µA. Input reference level CLK = 2.0V. Input reference level for all other inputs is
1.5V. Test VIH = 3.0V, VIHC = 4.0V, VIL = 0V, VILC = 0V.
6. Controlled via design or process parameters and not directly tested. Characterized upon initial design and after major process and/or Design
changes.
AC Test Load Circuit
NOTE:
7. Test Head Capacitance.
DUT
S1
(NOTE 7) CL
SWITCH S1 OPEN FOR
ICCSB AND ICCOP
IOH ± 1.5V
IOL
EQUIVALENT CIRCUIT
8