26h : Power Down (Read/Write, Default: 000xh)
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
EAPD - PR5 PR4 PR3 PR2 PR1 PR0 -
-
-
- REF ANL DAC ADC
EAPD............This bit controls the state of EAPD (No.47) pin.
“0” : Low
“1” : High
PR5 ...............Keep this bit to “0”.
PR4 ...............This bit controls the power state of the AC-Link.
“0” : Normal
“1” : Powar down
PR3 ...............This bit controls the power state of the analog mixer.
“0” : Normal
“1” : Powar down (Vref off)
PR2 ...............This bit controls the power state of the analog mixer.
“0” : Normal
“1” : Powar down (Vref still on)
PR1 ...............This bit controls the power state of the D/A converter.
“0” : Normal
“1” : Powar down
PR0 ...............This bit controls the power state of the A/D converter.
“0” : Normal
“1” : Powar down
REF...............This bit is Read Only, and indicates the state of Vref.
“0” : Ground level
“1” : 2.5V
ANL..............This bit is Read Only, and indicates the state of the analog mixer.
“0” : The analog mixer does not work.
“1” : The analog mixer works normally.
DAC..............This bit is Read Only, and indicates the state of the D/A converter.
“0” : The D/A converter does not work.
“1” : The D/A converter works normally.
ADC..............This bit is Read Only, and indicates the state of the A/D converter.
“0” : The A/D converter does not work.
“1” : The A/D converter works normally.
Note) When YMF743 is the Secondary CODEC, PR4 is not cleared by Warm Reset.