PERFORMANCE DATA*
LCA210
LCA210
Typical LED Forward Voltage Drop
(N=50 Ambient Temperature = 25°C)
IF = 8mADC
35
30
25
20
15
10
5
0
1.17
1.19
1.21
1.23
1.25
LED Forward Voltage Drop (V)
LCA210
Typical IF for Switch Operation
(N=50 Ambient Temperature = 25°C)
(Load Current = 85mADC)
25
20
15
10
5
0
0.78 1.30 1.82 2.34 2.86 3.38 3.9
LED Current (mA)
LCA210
Typical Turn-Off Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 85mADC; IF = 8mADC)
25
20
15
10
5
0
0.0
0.1
0.2
0.3
0.4
0.5
0.6
Turn-Off (ms)
LCA210
Typical Blocking Voltage
vs. Temperature
430
425
420
415
410
405
400
395
-40 -20
0 20 40 60
Temperature (°C)
80 100
LCA210
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25°C)
(Load Current = 85mADC) IF=8mA
!#
!
#

#

#

22.9 23.3 23.7 24.1 24.5 24.9 25.3
On-Resistance ()
LCA210
Typical IF for Switch Dropout
(N=50 Ambient Temperature = 25°C)
(Load Current = 85mADC )
25
20
15
10
5
0
0.78 1.30 1.82 2.34 2.86 3.38 3.9
LED Current (mA)
LCA210
Typical Load Current vs. Temperature
180
160
140
120
100
80
60
40
16mA
20
8mA
0
-40 -20 0 20 40 60 80 100 120
Temperature (°C)
LCA210
Typical Turn-On vs. Temperature
(Load Current = 40mADC)
5.000
4.500
4.000
3.500
3.000
2.500
2.000
1.500
8mA
1.000
16mA
0.500
0
32mA
-40 -20 0 20 40 60 80 100
Temperature (°C)
LCA210
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25°C)
35
30
25
20
15
10
5
0
420 425 430 435 440 445 450
Blocking Voltage (V)
LCA210
Typical Turn-On Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 85mADC; IF = 8mADC)
25
20
15
10
5
0
0.6
0.7
0.8
.9
1.0
1.1
1.2
Turn-On (ms)
LCA210
Typical Leakage vs. Temperature
(Measured across Pins 5 & 6 or 7 & 8)
0.016
0.014
0.012
0.010
0.008
0.006
0.004
0.002
0
-40 -20 0
20 40 60
80 100
Temperature (°C)
LCA210
Typical Turn-Off vs. Temperature
(Load Current = 40mADC)
0.45
0.40
0.35
0.30
0.25
0.20
0.15
0.10
0.05
0
-40 -20
0 20 40 60
Temperature (°C)
8mA
80 100
The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact