datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

SFS2-DC12V 查看數據表(PDF) - Panasonic Corporation

零件编号
产品描述 (功能)
比赛名单
SFS2-DC12V
Panasonic
Panasonic Corporation Panasonic
SFS2-DC12V Datasheet PDF : 5 Pages
1 2 3 4 5
SFS
RATING
1. Coil data
Contact arrangement
4-poles
2 Form A 2 Form B
3 Form A 1 Form B
4 Form A 2 Form B
6-poles 5 Form A 1 Form B
3 Form A 3 Form B
Nominal coil
voltage
12V DC
24V DC
48V DC
12V DC
24V DC
48V DC
12V DC
24V DC
48V DC
12V DC
24V DC
48V DC
12V DC
24V DC
48V DC
Pick-up voltage
(at 20°C 68°F)
75%V or less of
nominal voltage
(Initial)
Drop-out voltage
(at 20°C 68°F)
10%V or more of
nominal voltage
(Initial)
Nominal
operating current
[±10%]
(at 20°C 68°F)
30mA
15mA
7.5mA
30mA
15mA
7.5mA
41.7mA
20.8mA
10.4mA
41.7mA
20.8mA
10.4mA
41.7mA
20.8mA
10.4mA
Coil resistance
[±10%]
(at 20°C 68°F)
400
1,600
6,400
400
1,600
6,400
288
1,152
4,608
288
1,152
4,608
288
1,152
4,608
Note: The nominal operating current will increase by approximately 2mA due to the LED on the LED indication type.
Nominal
operating power
(at 20°C 68°F)
Approx. 360mW
Approx. 500mW
Max. applied
voltage
(at 20°C 68°F)
110%V of
nominal voltage
2. Specifications (relay)
Characteristics
Item
Contact
Rating
Contact arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Min. switching capacity (Reference value)*1
Nominal operating power
Insulation resistance (Initial)
Between open contacts
Electrical
characteristics
Breakdown
voltage
(Initial)
Between contact sets
Mechanical
characteristics
Between contact and coil
Operate time (at 20°C 68°F)
Response time (at 20°C 68°F)*2
Release time (at 20°C 68°F)
Shock
resistance
Functional
Destructive
Vibration
resistance
Functional
Destructive
Mechanical
Expected life
Electrical
Conditions
Unit weight
Conditions for operation, transport and
storage*3
Max. Operating speed
Specifications
4-pole
6-pole
2 Form A 2 Form B 3 Form A 1 Form B 4 Form A 2 Form B 5 Form A 1 Form B 3 Form A 3 Form B
Max. 100 m(By voltage drop 6 V DC 1A)
Au flashed AgSnO2 type
6A 250V AC, 6A 30V DC
1,500VA, 180W
250V AC, 125V DC
6 A (Reduce by 0.1 A/°C for temperatures 70 to 85°C 158 to 185°F)
1mA 5V DC
360mW
500mW
Min. 1,000M(at 500V DC) Measurement at same location as “Breakdown voltage” section.
1,500 Vrms for 1 min. (Detection current: 10mA)
2,500 Vrms for 1 min.
(Detection current: 10mA);
7-8/9-10 between open contacts
2,500 Vrms for 1 min. (Detection current: 10mA);
7-8/11-12 between open contacts
9-10/13-14 between open contacts
11-12/13-14 between open contacts
4,000 Vrms for 1 min.
(Detection current: 10mA);
3-4/5-6 between open contacts
3-4/7-8 between open contacts
5-6/9-10 between open contacts
4,000 Vrms for 1 min. (Detection current: 10mA);
3-4/5-6 between open contacts
3-4/7-8 between open contacts
5-6/9-10 between open contacts
7-8/9-10 between open contacts
4,000 Vrms for 1min (Detection current: 10mA)
Max. 20ms (Nominal coil voltage applied to the coil, excluding contact bounce time)
Max. 8ms (Nominal coil voltage applied to the coil, excluding contact bounce time) (without diode)
Max. 20ms (Nominal coil voltage applied to the coil, excluding contact bounce time) (without diode)
Min. 200 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs)
Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms)
10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10µs)
10 to 55 Hz at double amplitude of 1.5 mm
Min. 107 (at 180 times/min.)
250 V AC 6 A resistive load: Min. 105 (at 20 times/min.)
30 V DC 6 A resistive load: Min. 105 (at 20 times/min.)
250 V AC 1 A resistive load: Min. 5×105 (at 30 times/min.)
30 V DC 1 A resistive load: Min. 5×105 (at 30 times/min.)
[AC 15] 240 V AC 2 A inductive load: Min. 105 (at 20 times/min., cosϕ = 0.3)
[DC 13] 24 V DC 1 A inductive load: Min. 105 (at 20 times/min., L/R = 48 ms)
Ambient temperature: –40°C to +85°C –40°F to +185°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at max. rating)
Approx. 20 g .71 oz
Approx. 23 g .81 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Response time is the time after the coil voltage turns off until the time when “a” contact turns off.
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
ASCTB119E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e

Share Link: 