Dual SPM Detector
15
MX641 PRELIMINARY INFORMATION
11. Maximum voice frequencies = 3.4kHz.
12. With the Input Amplifier gain at 0dB and the Bandpass Filter gain set at 0dB (Table 4); subtract 1.0dB from this
specification for each extra single dB of Bandpass Filter gain programmed.
Alternatively, with the input components as recommended in Figure 2, the sensitivity is as defined in Table 4.
13. Logic inputs with no internal pullup; Chip Select, Serial Data, Serial Clock, Output Enable, Output Select and Clock
In pins.
14. Logic inputs with an internal pullup; Preset Level and System Select pins.
15. Preset Level = ‘0’, System Select = don't care; Chip Select, Serial Clock and Serial Data inputs active;
see Table 3.
16. Preset Level = ‘1’, System Select = input active; Chip Select, Serial Clock and Serial Data inputs inactive;
see Table 3
17. Maximum Clock Output Fan out = 4 (including master)
6.2 Timing
Parameter
tPWH Serial Clock ‘High‘ Pulse Width
tPWL Serial Clock ‘Low’ Pulse Width
tCYC Serial Clock Period
tCSE Chip Select ‘Low’ to Clock ‘High’ Edge
tDH Data Hold Time
tDS Data Setup Time
Min.
250
250
600
450
50.0
250
Typ.
Max. Unit
ns
ns
ns
ns
ns
ns
CHIP SELECT
SERIAL CLOCK
SERIAL DATA
t CSE
t CYC
t CSH
tDS
tDH
tPWL
tPWH
BIT D5
Don't
Care
Data
BIT D4 D3
BIT D0
Figure 9: Data Load Timing for the Controlled Sensitivity Mode
© 1998 MXxCOM Inc.
www.mxcom.com Tele: 800 638-5577 910 744-5050 Fax: 910 744-5054
Doc. # 20480115.003
4800 Bethania Station Road, Winston-Salem, NC 27105-1201 USA
All trademarks and service marks are held by their respective companies.