40 kBd Link
System Performance Under recommended operating conditions unless otherwise specified.
Parameter
Data Rate
Link Distance
(Standard Cable)
Link Distance
(Improved Cable)
Propagation
Delay
Pulse Width
Distortion tPLH-tPHL
Symbol Min. Typ. Max. Units Conditions
dc
40 kBd BER ≤10-9, PRBS: 27 - 1
13
41
94 138
m
IFdc = 2 mA
m
IFdc = 60 mA
15
45
m
IFdc = 2 mA
111 154
m
IFdc = 60 mA
tPLH
4
µs RL = 3.3 kΩ, CL = 30 pF
tPHL
2.5
µs PR = -25 dBm, 1 m fiber
tD
7
µs -39 ≤PR≤- 14 dBm
RL = 3.3 kΩ, CL = 30 pF
Notes:
1. Estimated typical link life expectancy at 40°C exceeds 10 years at 60 mA.
2. The propagation delay for one metre of cable is typically 5 ns.
Ref.
Fig. 21
Note 1
Fig. 22
Note 1
Fig. 22, 25
Note 2
Fig. 23, 24
Figure 20. Typical 40 kBd interface circuit
120
100
80
60
40
20
10
6
4
HFBR-15X3/25X3
2
0°C–70°C
25°C
1
0 10 20 30 40 50 60 70 80 90 100
– CABLE LENGTH – METRES
Figure 21. Guaranteed system performance with standard cable
15
120
100
80
60
40
20
10
6
HFBR-15X3/25X3
4
0°C–70°C
25°C
2
0 10 20 30 40 50 60 70 80 90 100 110
– CABLE LENGTH – METRES
Figure 22. Guaranteed system performance with improved cable