datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

M62212FP 查看數據表(PDF) - MITSUBISHI ELECTRIC

零件编号
产品描述 (功能)
比赛名单
M62212FP
Mitsubishi
MITSUBISHI ELECTRIC  Mitsubishi
M62212FP Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
MITSUBISHI SEMICONDUCTORS <Standard Linear ICs>
M62212P/FP/GP
GENERAL PURPOSE DC-DC CONVERTER
2. FUNCTION DESCRIPION
1) Soft Start (The peripheral circuit is shown in Fig.1)
When the power is turned ON, input terminal IN is at 0V level. Therefore, the FB
terminal is fixed to High level. The DTC terminal goes up gradually starting from 0V
due to the internal charge current and the external CDTC.
When the level of DTC terminal reaches the lower limit of the triangular wave of the
oscillator, PWM comparator and the output circuit go into operation causing the output
voltage, "Vo" of the DC-DC converter to rise. The charge current is designed to be
approximately 45µA.
FB
OSC
DTC
1.0V
0.45V
OFF
External Tr collector
ON
Fig.2
2) DTC
The dead time control is set by installing a resistor between the DTC terminal and GND.
However, the DTC terminal serves as the short protection circuit also. Therefore, its set up
depends on whether the short protection circuit is used and not.
(When the short protection circuit is used)
At this time, the charge current for DTC is approximately 10µA . Therefore, RDTC should
be set to 40K~ 110K.
(When the short protection circuit is not used)
At this time, the charge current for DTC is approximately 45µA. Therefore, RDTC is set to
12KÅ`25K.
( 5/ 8 )

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]