datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

L9484(2003) 查看數據表(PDF) - STMicroelectronics

零件编号
产品描述 (功能)
比赛名单
L9484
(Rev.:2003)
ST-Microelectronics
STMicroelectronics ST-Microelectronics
L9484 Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
L9484
DIAGNOSTIC (Tcase = -35°C to +150°C unless otherwise specified)
Symbol
Parameter
Conditions
Min. Typ. Max. Units
VOV Over-Voltage
VSP + 1 VSP + VSP + 2
V
1.3
VL-SAT Lamp ON Saturation Voltage IL = 0.5A (sinked by ASVR)
>VL-ACT 1.33
1.45
V
VL-SAT-BO Lamp ON Voltage 2
IL < 0.5A, VGO = Open; Tcase = -
35°C to 85°C
3.8
5
V
VL-RLY Lamp OFF (Relay Drive)
Saturation Voltage (vs. B+)
IL = 750mA (Sourced by ASVR)
3 Tcase < 125C
1.85
V
TDELAY Fault Indication Delay Time
Delay before Lamp ON
0.9
1.1
1.3
s
2. This condition can happen when the connection between the battery and VGO or the output terminal of the generator is broken.
The 1.1 second delay is not required, and current is sinked by ASVR.
3. When no fault is detected the Lamp terminal is pulled up by ASVR.
FAULT INDICATION TABLE
Conditions
Initial KEY-ON Bulb and Wiring Check (Lamp ON for 1 sec ± 15% after initial KEY-ON)
VGO > VOV
VP < VP-F AND VGO < VSP
FP < FP-TR @ VP-TR
No Connection Between Battery and VGO
At Start: Lamp ON until FP>FP-IR AND VP>VP-F. i.e. until VP reaches 8V.
TDelay?
No
Yes
Yes
Yes
No
No
REGULATION FEATURES
Symbol
Parameter
Conditions
VL-PD L Terminal Regulator Activate
Threshold
VGO=12.6V
IL-PD L Terminal Pull Down Current
VL = VL-ACT
VGO=12.6V
VP-IR Initiate Regulation Phase Voltage Regulator Activated
Threshold
VP-TR Terminate Regulation Phase
Voltage Threshold
Regulator Activated
VP-F Phase Input Voltage Low FAULT
Threshold
IP Phase Terminal Current Sink
VP > 1.5V and < 12.6V
VGO = 12.6V
FP-IR Initiate Regulation Phase
Frequency
Min. Typ. Max. Unit
0.8
1
1.15
V
0.09
0.78 mA
1.1
1.3
1.5
V
1.1
1.3
1.5
V
7.0
8
9.0
V
0.3
3.5
mA
123 145 167
Hz
5/8