MLX90719
General purpose timer
Low power RC oscillator
In case of applications without battery or crystal (OXBAT = 0) the MLX90719 uses an on-chip low power RC os-
cillator to count time during a few minutes after the mains has been disconnected (low power mode).
Parameter
Symbol Test Conditions
Min Typ Max Units
Master frequency of the Fckl
low power RC oscillator
Over full temp. and supply range
1.0 2.5 5 kHz
Notes:
As the CPU must calibrate it in normal mode, the low power oscillator is running continuously.
The low power RC oscillator is disabled if OXBAT = 1.
LCD outputs
The MLX90719 has 15 configurable LCD outputs able to drive either a backplane or a segment by mask option:
OLCDx = 0 => segment
OLCDx = 1 => backplane
The LCD voltages are defined according to bits LCDx and CKLCD written in P3 and P4 (see section “I/O
ports”). With Vcdl1 and Vlcd2 being respectively 1/3Vlcd and 2/3Vlcd, the MLX90719 is suitable for LCD having
1, 2, 3 or 4 backplanes.
Parameter
Symbol Test Conditions
Min Typ Max Units
Output impedance
Rolcd All cases
20 kohm
OLCDx
0
0
0
0
1
1
1
1
LCDx
0
0
1
1
0
0
1
1
CKLCD
0
1
0
1
0
1
0
1
OUT
Vlcd1
Vlcd2
Vlcd
Vss
Vlcd2
Vlcd1
Vss
Vlcd
Relay drivers
The MLX90719 includes 3 pull-down power outputs A, B, and C able to drive relays, triacs or LED’s.
The gates of the drivers are controlled respectively by signals POUTA, POUTB and POUTC generated by the
digital core (see section “PWM generator”).
Each driver has its source and its drain connected to a pad (DRAINx and SOURCEx) except driver C of which
the source is connected to the ground. This allows a series connection of the drivers. In such a configuration
the current flowing through the relay is used to feed the LED’s.
Internal current generator
In applications based on the following schematic, where the LED(‘s) may have to be driven when the relay is
off, an internal current peak generator can be activated to supply the LED’s through pin SourceA. This function
is enabled by bit INTCUR of P5 (see section “I/O ports”). When INTCUR is set the current generator is acti-
vated like a relay by signal PINT at frequency Fpwm and at 14.3% duty cycle (see “PWM generator”).
Note: If the application has no relay, this feature allows the MLX90719 to drive 2 LED’s without any external