datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

PI6C9911J 查看數據表(PDF) - Pericom Semiconductor

零件编号
产品描述 (功能)
比赛名单
PI6C9911J Datasheet PDF : 9 Pages
1 2 3 4 5 6 7 8 9
PI6C9911 & PI6C9911E
5V High Speed Programmable Skew
Clock Buffers - SuperClock®
111222333444555666777888999000111222333444555666777888999000111222333444555666777888999000111222111222333444555666777888999000111222333444555666777888999000111222333444555666777888999000111222111222333444555666777888999000111222333444555666777888999000111222333444555666777888999000111222111222333444555666777888999000111222333444555666777888999000111222333444555666777888999000111222111222333444555666777888999000111222
Pin Definitions
Signal Name
REF
FB
FS
1F0, 1F1
2F0, 2F1
3F0, 3F1
4F0, 4F1
TEST
1Q0, 1Q1
2Q0, 2Q1
3Q0, 3Q1
4Q0, 4Q1
VCCN
VCCQ
GND
I/O
I
O
PWR
Description
Reference frequency input. This input supplies the frequency and timing reference which all
functional variation is measured.
PLL feedback input (typically connected to one of the eight outputs).
Three-level frequency range select. See Table 1.
Three-level function select inputs for output pair 1 (1Q0, 1Q1). See Table 2.
Three-level function select inputs for output pair 2 (2Q0, 2Q1). See Table 2.
Three-level function select inputs for output pair 3 (3Q0, 3Q1). See Table 2.
Three-level function select inputs for output pair 4 (4Q0, 4Q1). See Table 2.
Three-level select. See test mode section under the block diagram descriptions.
Output pair 1. See Table 2.
Output pair 2. See Table 2.
Output pair 3. See Table 2.
Output pair 4. See Table 2.
Power supply for output drivers.
Power supply for internal circuitry.
Ground
Block Diagram Description
Phase Frequency Detector and Filter
These two blocks accept input signals from the reference frequency
(REF) input and the feedback (FB) input and generate correction
information to control the frequency of the Voltage-Controlled
Oscillator (VCO). These blocks, along with the VCO, form a Phase-
Locked Loop (PLL) that tracks the incoming REF signal.
VCO and Time Unit Generator
The VCO accepts analog control inputs from the PLL filter block
and generates a frequency that is used by the time unit generator to
create discrete time units that are selected in the skew mix matrix.
The operational range of the VCO is determined by the FS control
pin. The time unit (tU) is determined by the operating frequency of
the device and the level of the FS pin as shown in Table 1.
Skew Select Matrix
The skew select matrix is comprised of four independent sections.
Each section has two low-skew, high-fanout drivers (xQ0, xQ1),
and two corresponding three-level function select (xF0, xF1)
inputs. Table 2 shows the nine possible output functions for each
section as determined by the function select inputs. All times are
measured with respect to the REF input assuming that the output
connected to the FB input has 0tU selected.
2
PS8451B 03/28/01

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]