MITSUBISHI INTELLIGENT POWER MODULES
PM200DVA120
FLAT-BASE TYPE
INSULATED PACKAGE
Absolute Maximum Ratings, Tj = 25°C unless otherwise specified
Ratings
Symbol
Power Device Junction Temperature
Tj
Storage Temperature
Tstg
Case Operating Temperature
TC
Mounting Torque, M6 Mounting Screws
—
Mounting Torque, M6 Main Terminal Screws
—
Module Weight (Typical)
—
Supply Voltage (Applied between C1-E2)
Supply Voltage Protected by SC (VD = 13.5 ~16.5V, Inverter Part, Tj = 125°C Start)
Isolation Voltage (Main Terminal to Baseplate, AC 1 min.)
VCC(surge)
VCC(prot.)
Viso
Control Sector
Supply Voltage (Applied between VP1-VPC, VN1-VNC)
Input Voltage (Applied between CP1-VPC, VN1-VNC)
Fault Output Supply Voltage (Applied between FPO-VPC, FNO-VNC)
Fault Output Current (Sink Current at FPO, FNO Terminal)
VD
VCIN
VFO
IFO
IGBT Inverter Sector
Collector-Emitter Voltage (VD = 15V, VCIN = 5V)
Collector Current, (TC = 25°C)
Peak Collector Current, (TC = 25°C)
Collector Dissipation (TC = 25°C)
VCES
IC
ICP
PC
PM200DVA120
-20 to 150
-40 to 125
-20 to 100
3.92 ~ 5.88
3.92 ~ 5.88
510
1000
800
2500
20
20
20
20
1200
200
400
962
Units
°C
°C
°C
N·m
N·m
Grams
Volts
Volts
Vrms
Volts
Volts
Volts
mA
Volts
Amperes
Amperes
Watts
Sep.1998