M54/M74HC352/353
RECOMMENDED OPERATING CONDITIONS
Symbol
VCC
VI
VO
Top
tr, tf
Parameter
Supply Voltage
Input Voltage
Output Voltage
Operating Temperature: M54HC Series
M74HC Series
Input Rise and Fall Time
VCC = 2 V
VCC = 4.5 V
VCC = 6 V
Value
2 to 6
0 to VCC
0 to VCC
-55 to +125
-40 to +85
0 to 1000
0 to 500
0 to 400
Unit
V
V
V
oC
oC
ns
DC SPECIFICATIONS
Symbol
Parameter
VIH High Level Input
Voltage
VIL Low Level Input
Voltage
VOH High Level
Output Voltage
VOL Low Level Output
Voltage
II
Input Leakage
Current
IOZ 3 State Output
Off State Current
(for HC353)
ICC Quiescent Supply
Current
Test Conditions
VCC
(V)
2.0
4.5
6.0
2.0
4.5
6.0
2.0
4.5
VI =
VIH
IO=-20 µA
6.0 or
4.5 VIL IO=-4.0 mA
6.0
IO=-5.2 mA
2.0
4.5
VI =
VIH
IO= 20 µA
6.0 or
4.5 VIL IO= 4.0 mA
6.0
IO= 5.2 mA
6.0 VI = VCC or GND
TA = 25 oC
54HC and 74HC
Min. Typ. Max.
1.5
3.15
4.2
0.5
1.35
1.8
1.9 2.0
4.4 4.5
5.9 6.0
4.18 4.31
5.68 5.8
0.0 0.1
0.0 0.1
0.0 0.1
0.17 0.26
0.18 0.26
±0.1
Value
-40 to 85 oC
74HC
Min. Max.
1.5
3.15
4.2
0.5
1.35
1.8
1.9
4.4
5.9
4.13
5.63
0.1
0.1
0.1
0.33
0.33
±1
-55 to 125 oC
54HC
Min. Max.
1.5
3.15
4.2
0.5
1.35
1.8
1.9
4.4
5.9
4.10
5.60
0.1
0.1
0.1
0.40
0.40
±1
VI = VIH or VIL
6.0 VO = VCC or GND
±0.5
±5
±10
6.0 VI = VCC or GND
4
40
80
Unit
V
V
V
V
µA
µA
µA