MOSEL VITELIC
AC Characteristics
TA = 0° to 70°C; VSS = 0V; VCC = 3.3V ± 0.3V, tT = 1 ns
#
Symbol Parameter
Clock and Clock Enable
1
tCK
Clock Cycle Time
CAS Latency = 3
CAS Latency = 2
2
tCK
Clock Frequency
CAS Latency = 3
CAS Latency = 2
3
tAC
Access Time from Clock
CAS Latency = 3
CAS Latency = 2
4
tCH
Clock High Pulse Width
5
tCL
Clock Low Pulse Width
6
tT
Transition Tim
Setup and Hold Times
7
tIS
Input Setup Time
8
tIH
Input Hold Time
9
tCKS
Input Setup Time
10
tCKH
CKE Hold Time
11
tRSC
Mode Register Set-up Time
12
tSB
Power Down Mode Entry Time
Common Parameters
13
tRCD
14
tRP
15
tRAS
16
tRC
17
tRRD
18
tCCD
Refresh Cycle
Row to Column Delay Time
Row Precharge Time
Row Active Time
Row Cycle Time
Activate(a) to Activate(b) Command Period
CAS(a) to CAS(b) Command Period
19
tREF
Refresh Period (8192 cycles)
20
tSREX
Self Refresh Exit Time
V436616Y24VATG-75
Limit Values
-75
Min.
Max.
Unit
Note
s
7.5
ns
10
ns
133
MHz
100
MHz
2, 4
5.4
ns
_
6
ns
2.5
ns
2.5
ns
0.3
1.2
ns
1.5
ns
5
0.8
ns
5
1.5
ns
5
0.8
ns
5
15
ns
0
7.5
ns
20
ns
6
20
ns
6
45
100K
ns
6
60
ns
6
15
ns
6
1
CLK
64
ms
10
ns
V436616Y24VATG-75 Rev. 1.3 October 2001