datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MAX2640 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
比赛名单
MAX2640 Datasheet PDF : 9 Pages
1 2 3 4 5 6 7 8 9
MAX2640/MAX2641
300MHz to 2500MHz SiGe
Ultra-Low-Noise Amplifiers
Absolute Maximum Ratings
VCC to GND ............................................................-0.3V to +6V
RFIN Power (50Ω source) (Note 1)..................................+5dBm
Continuous Power Dissipation (TA = +70°C)
SOT23-6 (derate 8.7mW/°C above +70°C)..................696mW
Operating Temperature Range
MAX2640EUT/MAX2641EUT.............................. -40°C to +85°C
MAX2640AUT.................................................... -40°C to +125°C
Storage Temperature Range............................. -65°C to +160°C
Lead Temperature (soldering, 10s).................................. +300°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these
or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect
device reliability.
Note 1: Pin must be AC-coupled with a DC blocking capacitor.
CAUTION! ESD SENSITIVE DEVICE
DC Electrical Characteristics
(VCC = +2.7V to +5.5V, TA = -40°C to +85°C (MAX2640EUT/MAX2641EUT), TA = -40°C to +125°C (MAX2640AUT), unless otherwise
noted. Typical values are at VCC = +3.0V, TA = +25°C.) Limits at TA = +25°C are guaranteed by production test. Limits over temperature
are guaranteed by design and characterization.
PARAMETER
CONDITIONS
MIN TYP MAX UNITS
Operating Supply Voltage
2.7
5.5
V
TA = +25°C
3.5
4.7
Operating Supply Current
TA = -40°C to +85°C
(MAX2640EUT/MAX2641EUT)
6.4
mA
TA = -40°C to +125°C (MAX2640AUT)
7.8
RF Electrical Characteristics
(VCC = +3.0V, PRFIN = -34dBm, ZO = 50Ω, TA = +25°C, unless otherwise noted.) (Notes 2 and 3)
PARAMETER
CONDITIONS
MIN
MAX2640 (fRFIN = 900MHz)
RFIN Frequency Range
300
Gain
12.8
Gain Variation Over Temperature
Noise Figure
TA = -40°C to +85°C (MAX2640EUT)
TA = -40°C to +125°C (MAX2640AUT)
(Note 4)
Input Return Loss
Output Return Loss
Reverse Isolation
Input 1dB Gain Compression Point
Input Third-Order Intercept Point
(Note 5)
MAX2641 (fRFIN = 1900MHz)
RFIN Frequency Range
1400
Gain
12.4
Gain Variation Over Temperature
Noise Figure
TA = TMIN to TMAX
(Note 4)
Input Return Loss
Output Return Loss
Reverse Isolation
Input 1dB Gain Compression Point
Input Third-Order Intercept Point
(Note 6)
TYP
15.1
0.6
0.9
0.9
-11
-14
40
-22
-10
14.4
0.9
1.3
-12
-12
30
-21
-4
MAX UNITS
1500
1.7
2.5
1.1
MHz
dB
dB
dB
dB
dB
dB
dBm
dBm
2500
2.4
1.5
MHz
dB
dB
dB
dB
dB
dB
dBm
dBm
www.maximintegrated.com
Maxim Integrated 2

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]