6. Operate/release time characteristics
Tested sample: HX2-12V, 10 pcs.
6
5
4
3
Set time
Max.
2
Min.
Reset time
Max.
1
Min.
0
80 90 100 110 120
Coil applied voltage, %V
7. Distribution of pick-up and drop-out voltage
Tested sample: HX2-12V, 50 pcs.
35
30 Drop-out voltage
25
Pick-up voltage
20
15
10
5
0 10 20 30 40 50 60 70 80 90 100
Ratio against the rated voltage, %V
HX
8. Ambient temperature characteristics
Tested sample: HX2-12V, 5 pcs.
–40
–30 Drop-out
voltage
–20
–40 –20
–10
0
Pick-up voltage
20 40 60 80
Ambient temperature, °C
–10
–20
–30
–40
9. Distribution of contact resistance
Tested sample: HX2-12V, 25 pcs. (25 × 4 contacts)
50
40
30
20
10
0
20
30
40
Contact resistance, m
10.-(1) High frequency characteristics
Isolation characteristics
100
50
10
100
Frequency, MHZ
1,000
10.-(2) High frequency characteristics
Insertion loss characteristics
0.5
0.4
0.3
0.2
0.1
0
10
100
Frequency, MHZ
1,000
NOTES
1. Coil operating power
Pure DC current should be applied to the
coil.The wave form should be rectangular.
If it includes ripple, the ripple factor should
be less than 5%.
However, check it with the actual circuit
since the characteristics may be slightly
different. The nominal operating voltage
should be applied to the coil for more than
10 ms to set/reset the latching type relay.
2. Cleaning
In automatic cleaning, cleaning with the
boiling method is recommended. Avoid ul-
trasonic cleaning which subject the relay
to high frequency vibrations. It may cause
the contacts to stick.
lt is recommended that a fluorinated hy-
drocarbon or other alcoholic solvent be
used.
3. Packing style
• Packing direction
The relay is packed in a tube with the relay
orientation mark on the left side, as shown
in the figure below.
Take note of the relay orientation when
mounting relays on the printed circuit
board.
Orientation (indicates PIN No. 1) stripe
Stopper
(gray)
Stopper
(green)
The temperature range is –40 to +70°C
–40 to +158°F
4. Automatic insertion
To maintain the internal function of the re-
lay, the chucking pressurre should not ex-
ceed the values below.
Chucking pressure in direction A:
9.8 N {1 kgf} or less
Chucking pressure in direction B:
9.8 N {1 kgf} or less
Chucking pressure in direction C:
4.9 N {500 gf} or less
C
A
B
Please chuck the portion.
Avoid chucking the center of the relay.
For Cautions for Use, see Relay Technical Information (Page 48 to 76).
9/1/2000
All Rights Reserved, © Copyright Matsushita Electric Works,1L8td5.
Go To Online Catalog

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]