Model
Number
Input
Range
Output Output Current
Output (4)
Input Current Eff (4) Load
Voltage Min. load Full load Ripple & Noise No load(3) Full load(2) (%) regulation
QEB50-24S3P3 18 – 36 VDC 3.3 VDC
0mA
15A
100mVp-p
70mA
2398mA
90
10mV
QEB50-24S05 18 – 36 VDC 5 VDC
0mA
10A
100mVp-p
120mA
2394mA
91
15mV
QEB50-24S12 18 – 36 VDC 12 VDC
0mA
4.17A
100mVp-p
180mA
2413mA
91
36mV
QEB50-24S15 18 – 36 VDC 15 VDC
0mA
3.33A
100mVp-p
180mA
2392mA
91
45mV
QEB50-48S1P8 36 – 75 VDC 1.8 VDC
0mA
20A
100mVp-p
55mA
904mA
87
5.4mV
QEB50-48S2P5 36 – 75 VDC 2.5 VDC
0mA
20A
100mVp-p
55mA
1240mA
88
7.5mV
QEB50-48S3P3 36 – 75 VDC 3.3 VDC
0mA
15A
100mVp-p
70mA
1199mA
90
10mV
QEB50-48S05 36 – 75 VDC 5 VDC
0mA
10A
100mVp-p
65mA
1197mA
91
15mV
QEB50-48S12 36 – 75 VDC 12 VDC
0mA
4.17A
100mVp-p
120mA
1207mA
91
36mV
QEB50-48S15 36 – 75 VDC 15 VDC
0mA
3.33A
100mVp-p
120mA
1196mA
91
45mV
Note :
1.BELLCORE TR-NWT-000332. Case 1: 80% Stress, Temperature at 40ºC.
MIL-HDBK-217F Notice2 @Ta=25 ºC, Full load(Ground, Benign, controlled environment)
2.Maximum value at nominal input voltage and full load of standard type.
3.Typical value at nominal input voltage and no load.
4.Typical value at nominal input voltage and full load.
5.Maximum output deviation is 10% inclusive of trim. If remote sense is not being used, the + sense should be connected to its corresponding
+OUTPUT and likewise the –sense should be connected to its corresponding –OUTPUT.
6.The positive logic and pin length are optional ( see table ). The pin voltage is referenced to –Vin.
7.Heat sink is optional and P/N7G-0029A-F, 7G-0030A-F, 7G-0031A-F, 7G-0032A-F.
8.The QEB50 meets EN55022 class A and class B only with external components connected before the input pin to the converter.
9.An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
The filter capacitor Power Mate suggest: Nippon chemi-con KY series, 220μF/100V, ESR 48mΩ.
10.BASEPLATE GROUNDINGBase-plate should be grounded at one of the four screw bolts prior to operation.
11.The converter is provided by basic insulation.