datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

GS9028 查看數據表(PDF) - Unspecified

零件编号
产品描述 (功能)
比赛名单
GS9028 Datasheet PDF : 7 Pages
1 2 3 4 5 6 7
The termination resistor (RT) value should be equal to the
characteristic impedance of the cable. Controlled
impedance traces should be used for the outputs and the
termination resistors should be placed near the GS9028.
The inductor (L) and resistor (R) are used to optimize the
output return loss and are PCB dependent. Typically, R
equals the transmission line characteristic impedance and
L is approximately 8.2nH.
OUTPUT AMPLITUDE ADJUSTMENT
The GS9028 outputs are adjustable from as low as 50mV to
as high as 1000mV. The output amplitude is set by the RSET
resistor connected to pin 4. The relationship between the
output amplitude (VOUT) and RSET is approximately given by
the equation below:
RSET = (1.3696 x ZO)/(2 x VOUT) - 5.5
where ZO is in ohms and VOUT is in volts.
The minimum value of RSET is 46. For 75cable and
800mV output amplitudes, the value of RSET is 59. Also,
note that the above formula assumes that the transmission
line is properly end terminated.
TYPICAL APPLICATION CIRCUIT
5
VEE
6
SDI
4
RSET
59
3
VEE
7
GS9028
2
SDI
SDO
8
VCC
1
SDO
75
8.2nH 1µ
8.2nH 1µ
75
75 75
100n
VCC
10n
VCC
All resistors in ohms, all capacitors in farads, unless otherwise shown.