datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MAX4578 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
比赛名单
MAX4578 Datasheet PDF : 20 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
High-Voltage, Single 8-to-1/
Dual 4-to-1 Cal-Multiplexers
ELECTRICAL CHARACTERISTICS—Single +12V Supply (continued)
(V+ = +12V, V- = 0, logic levels = 2.4V and 0.8V, TA = TMIN to TMAX, unless otherwise noted. Typical values are at TA = +25°C.) (Note 2)
PARAMETER
SYMBOL
CONDITIONS
SWITCH (continued)
COM Off-Leakage
Current (Notes 5, 9)
COM On-Leakage
Current (Notes 5, 9)
LOGIC INPUTS
Input High Voltage
Input Low Voltage
Input Current with
Input Voltage High
ICOM_(OFF)
VCOM_ = 11V, 1V;
VNO_ = 1V, 11V
VCOM_ = 11V, 1V;
ICOM_(ON) VNO_ = 11V, 1V,
or floating
MAX4578
MAX4579
MAX4578
MAX4579
TA = +25°C
TA = TMIN to TMAX
TA = +25°C
TA = TMIN to TMAX
TA = +25°C
TA = TMIN to TMAX
TA = +25°C
TA = TMIN to TMAX
VIH
VIL
IIH
VEN = VA_ = VLATCH = VCAL = V+
Input Current with
Input Voltage Low
IIL
VEN = VA_ = VLATCH = VCAL = 0
DYNAMIC CHARACTERISTICS (Note 3)
Transition Time
tTRANS VNO1 = 8V, VNO8 = 0, Figure 1
Break-Before-Make
Interval
tOPEN Figure 2
TA = +25°C
TA = TMIN to TMAX
TA = +25°C
Enable Turn-On Time
Enable Turn-Off Time
tON Figure 3
tOFF Figure 3
TA = +25°C
TA = TMIN to TMAX
TA = +25°C
TA = TMIN to TMAX
MIN
-0.05
-6.5
-0.05
-3.25
-0.05
-6.5
-0.05
-3.25
2.4
-1
-1
120
TYP
0.005
0.005
0.006
1.8
1.8
0.001
0.001
600
400
540
150
MAX UNITS
0.05
6.5
nA
0.05
3.25
0.05
6.5
nA
0.05
3.25
V
0.8
V
1
µA
1
µA
850
ns
1100
ns
800
ns
1100
315
ns
450
Note 2: The algebraic convention, where the most negative value is a minimum and the most positive value a maximum, is used in
this data sheet.
Note 3: Guaranteed by design.
Note 4: RON = RON(MAX) - RON(MIN).
Note 5: Leakage parameters are 100% tested at maximum-rated hot temperature and guaranteed by correlation at TA = +25°C.
Note 6: If the logic inputs can float during power-on, connect a 1Mpull-up from LATCH to V+. See Applications Information section.
Note 7: Off-Isolation = 20log10 (VCOM / VNO), VCOM = output, VNO = input to off switch.
Note 8: Between any two switches.
Note 9: Leakage parameters testing at single supply are guaranteed by correlation with dual supplies.
_______________________________________________________________________________________ 7

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]