High-Linearity, 815MHz to 1000MHz Upconversion/
Downconversion Mixer with LO Buffer/Switch
AC ELECTRICAL CHARACTERISTICS (UPCONVERTER OPERATION)
(Typical Application Circuit, L1 = 4.7nH, C4 = 4.7pF, C5 not used, VCC = +4.75V to +5.25V, RF and LO ports are driven from 50Ω
sources, PLO = -3dBm to +3dBm, PIF = 0dBm, fRF = 815MHz to 1000MHz, fLO = 570MHz to 900MHz, fIF = 90MHz, fLO < fRF,
TC = -40°C to +85°C, unless otherwise noted. Typical values are at VCC = +5V, PLO = 0dBm, fRF = 920MHz, fLO = 830MHz,
fIF = 90MHz, TC = +25°C, unless otherwise noted.) (Note 1)
PARAMETER
Conversion Loss
Conversion Loss Flatness
Conversion Loss Variation Over
Temperature
Input Compression Point
Input Third-Order Intercept Point
Input IP3 Variation Over
Temperature
LO ± 2IF Spur
LO ± 3IF Spur
Output Noise Floor
SYMBOL
CONDITIONS
MIN
GC
Flatness over any one of four frequency
bands (fIF = 90MHz):
fRF = 827MHz to 849MHz
fRF = 869MHz to 894MHz
fRF = 880MHz to 915MHz
fRF = 920MHz to 960MHz
TC = +25°C to -40°C
TC = +25°C to +85°C
P1dB (Note 4)
fIF1 = 90MHz, fIF2 = 91MHz (results in
IIP3 fRF1 = 920MHz, fRF2 = 921MHz), PIF =
34
0dBm/tone, PLO = 0dBm, TC = +25°C (Note 3)
IIP3 TC = +25°C to -40°C
TC = +25°C to +85°C
POUT = 0dBm (Note 5)
TYP MAX UNITS
6
dB
±0.3
dB
-0.4
0.3
25
39
-0.6
-0.6
71
86
-167
dB
dBm
dBm
dB
dBc
dBc
dBm/Hz
Note 1: All limits include external component losses. Output measurements are taken at IF or RF port of the Typical Application Circuit.
Note 2: Operation outside this range is possible, but with degraded performance of some parameters.
Note 3: Guaranteed by design.
Note 4: Compression point characterized. It is advisable not to continuously operate the mixer RF/IF inputs above +15dBm.
Note 5: Measured with external LO source noise filtered, so its noise floor is -174dBm/Hz at 100MHz offset. This specification reflects the
effects of all SNR degradations in the mixer, including the LO noise as defined in Maxim Application Note 2021.
4 _______________________________________________________________________________________