datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

DG9053DQ-T1-E3 查看數據表(PDF) - Vishay Semiconductors

零件编号
产品描述 (功能)
比赛名单
DG9053DQ-T1-E3 Datasheet PDF : 13 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
DG9051, DG9052, DG9053
Vishay Siliconix
SPECIFICATIONS (Single Supply 3 V)
Parameter
Analog Switch
Symbol
Test Condition
Unless Otherwise Specified
V + = 3 V, ± 10 %, V - = 0 V
VEN = 0.4 V or 2 V
Limits
- 40 °C to 85°C
Temp.b Min.c Typ.d Max.c Unit
Analog Signal Rangee
VANALOG
Full
0
3
V
On-Resistance
RON Match Between Channelsg
Switch Off Leakage Currenta
RON
RON
IS(off)
ID(off)
V + = 2.7 V, VD = 1.5 V, IS = 0.1 mA
V + = 2.7 V, VD = 1.5 V, IS = 0.1 mA
V + = 3.3 V, VEN = 2 V
VS = 3 or 0.3 V, VD = 0.3 or 3 V
Room
Room
130
12
Room - 1
Full
- 20
Room - 1
Full
- 20
1
20
1
20
nA
Channel On Leakage Currenta ID(on)
V + = 3.3 V, VEN = 0 V
VS = 3 or 0.3 V, VD = 0.3 or 3 V
Room - 2
Full
- 10
2
10
Digital Control
Logic High Input Voltage
Logic Low Input Voltage
Input Currenta
VINH
VINL
IIN
VAX = VEN = 2 V or 0.4 V
Full
2
Full
Full
-1
V
0.4
1
µA
Dynamic Characteristics
Transition Time
tTRANS
V + = 2.7 V, VNO/NC = 1.5 V/0 V, 0 V/1.5 V
RL = 300 , CL = 35 pF
Room
80
Break-Before-Make Time
tBBM
V + = 2.7 V, VX,Y, Z = 1.5 V, VS = 0 V,
Room
25
Full
5
ns
Enable Turn-On Time
tON(EN)
RL = 300 , CL = 35 pF
Room
90
Enable Turn-Off Time
tOFF(EN)
Room
30
Charge Injectione
Q
CL = 1 nF, VGEN = 0 V, RGEN = 0
Room
9
pC
Off-Isolatione,h
Crosstalke
OIRR
XTALK
Room
- 78
f = 1 MHz, RL = 50
dB
Room
- 83
Source Off Capacitancee
CS(off)
f = 1 MHz, VS = 0 V, VEN = 1.8 V
Room
5
Drain Off Capacitancee
CD(off)
f = 1 MHz, VD = 0 V, VEN = 1.8 V
Room
10
pF
Drain On Capacitancee
CD(on)
f = 1 MHz, VD = 0 V, VEN = 0 V
Room
15
Power Supply
Power Supply Current
I+
VEN = VA = 0 V or V +
Room
1
µA
Notes:
a. Leakage parameters are guaranteed by worst case test condition and not subject to production test.
b. Room = 25°C, Full = as determined by the operating temperature suffix.
c. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
d. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
e. Guaranteed by design, not subject to production test.
f. VIN = input voltage to perform proper function.
g. RDON = RDON Max - RDON Min.
h. Worst case isolation occurs on Channel 4 due to proximity to the drain pin.
i. RDON flatness is measured as the difference between the minimum and maximum measured values across a defined Analog signal.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
www.vishay.com
Document Number: 73410
6
S11-1066-Rev. B, 30-May-11
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000

Share Link: 