Common Specifications
Item
Specifications
Enclosure rating *4
Semi-closed (IP20)
Control method
Phase-to-phase sinusoidal modulation PWM
Output frequency range *5 0.5 to 400 Hz
Frequency precision *6
Digital command: ±0.01% of the max. frequency
Analog command:±0.4% of the max. frequency (25°C ±10°C)
Frequency setting
resolution
Digital setting: 0.1 Hz
Analog setting: Max. frequency/1000
Control
Voltage/Frequency
characteristics
V/f characteristics (constant/reduced torque)
Overload current rating 150% for 1 min
Acceleration/
Deceleration time
0.01 to 3000 s (line/curve selection), 2nd acceleration/deceleration setting available
Carrier frequency
modification range
2 to 12 kHz
DC injection braking
Starts at a frequency lower than that in deceleration via the STOP command, at a value set lower than that during
operation, or via an external input. (Level and time settable.)
Protective functions
Overcurrent, overvoltage, undervoltage, electronic thermal, temperature error, ground-fault overcurrent at power-on
state, overload limit, incoming overvoltage, external trip, memory error, CPU error, USP trip, communication error,
overvoltage protection during deceleration, momentary power interruption protection, emergency shutoff
Input signal Multi-function input
FW (forward), RV (reverse), CF1 to CF4 (multi-step speed), JG (jogging), DB (external DC injection braking), SET (2nd
function), 2CH (2-step acceleration/deceleration), FRS (free run), EXT (external trip), USP (USP function), SFT (soft
lock), AT (analog current input function selection), RS (reset), PTC (thermistor input), STA (3-wire startup), STP (3-wire
stop), F/R (3-wire forward/reverse), PID (PID selection), PIDC (PID integral reset), UP (UP of UP/DWN function), DWN
(DWN of UP/DWN function), UDC (data clear of UP/DWN function), OPE (forced OPE mode), ADD (frequency addition),
F-TM (forced terminal block), RDY (operation ready), SP-SET (special setting), EMR (emergency shutoff)
Output
signal
Multi-function output
Frequency monitor
RUN (signal during operation), FA1 (frequency arrival signal 1), FA2 (frequency arrival signal 2), OL (overload warning
signal), OD (PID excess deviation signal), AL (alarm signal), DC (analog input disconnection detection signal), FBV (PID
FB status output), NDc (network error), LOG (logical operation result), ODc (communication option disconnected), LOC
(light load signal)
Analog output (0 to 10 V DC, 1 mA max.)
Frequency/Current signals are selectable via the AM output terminal.
Relay output
The relay (SPDT contact) outputs signals corresponding to the multi-function output.
Other functions
AVR function, V/f characteristic selection, upper/lower limit, 16-step speeds, starting frequency adjustment, jogging
operation, carrier frequency adjustment, PID control, frequency jump, analog gain/bias adjustment, S-shape
acceleration/deceleration, electronic thermal characteristics/level adjustment, retry function, simplified torque boost, trip
monitor, soft lock function, frequency conversion display, USP function, 2nd control function, motor rotation speed UP/
DOWN, overcurrent suppression function
Ambient temperature
10°C to 50°C (Both the carrier frequency and output current need to be reduced at over 40°C.)
General
specifica-
tions
Ambient storage
temperature
Humidity
Vibration
20°C to 65°C (short-time temperature during transport)
20% to 90% RH
5.9 m/s2 (0.6G), 10 to 55 Hz (Complies with the test method specified in JIS C0040 (1999).)
Location
At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust)
Applicable standard
Complies with UL, cUL, CE standards. (Insulation distance)
Options
Noise filter, AC/DC reactors, regenerative braking unit and resistor, etc.
*1. The applicable motor is a 3-phase standard motor. For using any other type, be sure that the rated current does not exceed that of the Inverter.
*2. Output voltage decreases according to the level of the power supply voltage.
*3. The braking torque at the time of capacitor feedback is an average deceleration torque at the shortest deceleration (when it stops from 50 Hz), not a continuous
regeneration torque. Also, the average deceleration torque varies depending on the motor loss. The value is reduced in operation over 50 Hz. Note that no regen-
erative braking circuit is built into the Inverter. If you need a larger regenerative torque, use the optionally available regenerative braking unit and resistor.
The regenerative braking unit should be used only for short-time regeneration.
*4. Protection method complies with JEM 1030.
*5. To operate the motor at over 50/60 Hz, contact the motor manufacturer to find out the maximum allowable speed of revolution.
*6. For the stable control of the motor, the output frequency may exceed the maximum frequency set in A004 (A204) by 2 Hz max.
Simple, Compact Inverters SYSDRIVE JX Series