datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MK2754S 查看數據表(PDF) - Integrated Circuit Systems

零件编号
产品描述 (功能)
比赛名单
MK2754S
ICST
Integrated Circuit Systems ICST
MK2754S Datasheet PDF : 4 Pages
1 2 3 4
I CR O C LOC K
MK2754
Low Cost 54 MHz VCXO
Electrical Specifications
Parameter
Conditions
ABSOLUTE MAXIMUM RATINGS (note 1)
Supply voltage, VDD
Referenced to GND
Inputs and Clock Outputs
Referenced to GND
Ambient Operating Temperature
Soldering Temperature
Max of 10 seconds
Storage temperature
DC CHARACTERISTICS (VDD = 5.0V unless noted)
Operating Voltage, VDD
Output High Voltage, VOH
IOH=-25mA
Output Low Voltage, VOL
IOL=25mA
Output High Voltage, VOH, CMOS level
IOH=-8mA
Operating Supply Current, IDD
No Load
Short Circuit Current
VIN, VCXO control voltage
AC CHARACTERISTICS (VDD = 5.0V unless noted)
Input Crystal Frequency
Input Crystal Accuracy
Output Clock Rise Time
0.8 to 2.0V
Output Clock Fall Time
2.0 to 0.8V
Output Clock Duty Cycle
At 1.4V
Maximum Absolute Jitter, short term
54 MHz output pullability, note 2
0V VIN 3V
Minimum Typical Maximum Units
7
V
-0.5
VDD+0.5 V
0
70
°C
260
°C
-65
150
°C
4.75
2.4
VDD-0.4
20
±100
0
5.25
V
V
0.4
V
V
mA
mA
3
V
13.50000
MHz
±30
ppm
1.5
ns
1.5
ns
40
50
60
%
200
ps
±100
ppm
Notes: 1. Stresses beyond those listed under Absolute Maximum Ratings could cause permanent damage to the device. Prolonged
exposure to levels above the operating limits but below the Absolute Maximums may affect device reliability.
2. With a MicroClock approved pullable crystal.
External Components
The MK2754 requires a minimum number of external components for proper operation. A decoupling
capacitor of 0.1µF should be connected between VDD and GND on pins 2 and 4, as close to the MK2754
as possible. A series termination resistor of 33may be used for the clock output. The input crystal must be
connected as close to the chip as possible. The input crystal should be a parallel mode, pullable, AT cut,
13.5MHz, with 14pF load capacitance. Consult MicroClock for recommended suppliers. IMPORTANT -
read application note MAN05 before laying out the PCB.
MDS 2754 B
3
Revision 011698
Printed 11/16/00
MicroClock Division of ICS•1271 Parkmoor Ave.•San Jose•CA•95126•(408)295-9800tel•(408)295-9818fax