µPD448012-X
DC Characteristics (Recommended Operating Conditions Unless Otherwise Noted) (1/2)
Parameter
Symbol
Test condition
VCC ≥ 2.7 V
Unit
µPD448012-BxxX
MIN. TYP.
MAX.
Input leakage current
ILI
VIN = 0 V to VCC
–1.0
I/O leakage current
ILO VI/O = 0 V to VCC, /CE1 = VIH or
–1.0
CE2 = VIL or /WE = VIL or /OE = VIH
Operating supply current
ICCA1 /CE1 = VIL, CE2 = VIH, Cycle time = 55 ns
–
Minimum cycle time, Cycle time ≥ 70 ns
–
II/O = 0 mA
ICCA2 /CE1 = VIL, CE2 = VIH, II/O = 0 mA,
–
Cycle time = ∞
ICCA3 /CE1 ≤ 0.2 V, CE2 ≥ VCC – 0.2 V,
–
Cycle time = 1 µs, II/O = 0 mA,
VIL ≤ 0.2 V, VIH ≥ VCC – 0.2 V
Standby supply current
ISB /CE1 = VIH or CE2 = VIL or /LB = /UB = VIH
–
ISB1 /CE1 ≥ VCC − 0.2 V, CE2 ≥ VCC − 0.2 V
1.0
ISB2 CE2 ≤ 0.2 V
1.0
ISB3 /LB = /UB ≥ VCC − 0.2 V,
1.0
/CE1 ≤ 0.2 V, CE2 ≥ VCC − 0.2 V
High level output voltage VOH IOH = –0.5 mA
2.4
Low level output voltage
VOL IOL = 1.0 mA
+1.0
µA
+1.0
µA
50
mA
45
4
6
0.6
mA
15
µA
15
15
V
0.4
V
Remarks 1. VIN : Input voltage, VI/O : Input / Output voltage
2. These DC characteristics are in common regardless of product classification.
6