datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

8842 查看數據表(PDF) - ASM GmbH

零件编号
产品描述 (功能)
比赛名单
8842
ASM-SENSOR
ASM GmbH ASM-SENSOR
8842 Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
7
- Function Details -
Real time save function *supported in version 2.60 or later
The real time save function enables data to be saved to
the PC card while waveform is being measured. The
compressed waveform is displayed on the screen at real
time. This function is valid at the recorder and memory
function. Write to the PC card can be up to 2kS/s
(=50ms/DIV) for 8 channels, or up to 1kS/s (100ms/
DIV) for 16 channels. With the real time save function,
data measured at the pre-determined sampling below the
maximum sampling can be saved to the PC card at any
time.
In addition, since the same data is compressed along the
time axis and displayed on the screen, you can check
how recording is going. Compressed data is saved to the
PC card for later retrieval.
Maximum continuous recording time using 256MB/1GB PC card
(with MEMORY BOARD 9608 expansion)
Time axis
Sampling
period
256MB PC card
1GB PC card
50ms/DIV
500μs
2 h 13 m 12 s
8 h 53 m 4 s
100ms/DIV
1ms
2 h 13 m 12 s
8 h 53 m 3 s
200ms/DIV
2ms
4 h 26 m 22 s
17 h 46 m 2 s
500ms/DIV
5ms
11 h 5 m 50 s
1 day 20 h 24 m 35 s
1s/DIV
10ms
22 h 11 m 20 s
3 days 16 h 47 m 50 s
2s/DIV
20ms
1 day 20 h 21 m 00 s
7 days 9 h 29 m 40 s
5s/DIV
50ms
4 days 14 h 41 m 40 s 18 days 11 h 00 m 00 s
10s/DIV
100ms
9 days 4 h 46 m 40 s 36 days 19 h 31 m 40 s
30s/DIV
300ms
27 days 7 h 5 m
109 days 5 h 40 m
1min/DIV
0.6s 53 days 17 h 00 m
208 days 8 h 00 m
2min/DIV
1.2s 104 days 1 h 00 m
208 days 8 h 00 m
5min/DIV
3.0s 208 days 0 h 00 m
208 days 8 h 00 m
Note: Saved at 8 channels for 50 ms/DIV, or at 16 channels otherwise.
Note: Maximum continuous recording time at MEM function, with time axis is 1 hour/DIV in REC function.
Note: Limit of maximum continuous recording time at MEM function is 208 days and 8 hours.
Storage data (MEM waveform) :
Save measurement data to the PC card at real time
Time axis setting(MEM): 50 ms/DIV to 5 minutes/DIV
(sampling frequency starting from 2 kS/s for 8 channels or from 1 kS/s for 16 channels)
Recording length setting (MEM): depending on free capacity of the PC card.
Input waveform
Storage data (REC waveform) :
Save compressed data to the PC card after
measurement
Time axis setting(REC): 200 ms/DIV to 1 hour/DIV
(sampling frequency starting from 2 kS/s for 8 channels or from 1 kS/s for
16 channels)
Recording length setting (REC): up to 1000 DIV (or up to 5000 DIV with
memory expansion)
Display data (REC waveform): compressed waveform is displayed on screen
Compressed data is saved temporarily in the internal memory.
However, display time axis of REC data is 2 steps later than that of MEM data. The maximum recording time that
can be set is determined by the free capacity of the PC card, and the time axis and recording length of MEM/REC.
Nevertheless, since the maximum recording length of REC is fixed at 1000 DIV, or 5000 DIV if there is memory
expansion, even if there is plenty of free capacity on the PC card, the recording time cannot exceed the value
determined by REC time axis multiplied by 1000 DIV.
Trigger functions capable of monitoring all 16 channels
For all of the measurement functions, including record and
memory recorder, triggers can be set on all 16 channels. In
addition to a simple level trigger based on comparison with a
single voltage value, the following trigger functions are also
available:
Window trigger based on 2 voltage values
Voltage drop trigger for AC power lines
Level trigger based on rms values
Cycle trigger monitoring the rising edge of a voltage
Pattern trigger monitoring the Hi/Low condition of a logic signal
Analog CH 1
Logic A
Analog CH 16
Logic D
EXT
trigger
Trigger
sources
AND/OR
MANUAL
trigger
Trigger levels
Timer
Effective value level trigger
Level trigger
Window trigger
Voltage-drop
detection trigger
Period detection trigger Logic pattern trigger