First Prev 21 22 23 24 25 26 27 28 29 30 Next Last
C505 / C505C
C505A / C505CA
Table 4
Special Function Registers - Functional Blocks
Block Symbol Name
Address Contents after
Reset
CPU
ACC
B
DPH
DPL
DPSEL
PSW
SP
SYSCON2)
Accumulator
B-Register
Data Pointer, High Byte
Data Pointer, Low Byte
Data Pointer Select Register
Program Status Word Register
Stack Pointer
System Control Register
VR0 4)
VR1 4)
Version Register 0
Version Register 1
VR2 4)
Version Register 2
E0H 1)
F0H 1)
83H
82H
92H
D0H 1)
81H
B1H
FCH
FDH
FDH
FEH
00H
00H
00H
00H
XXXXX000B 3)
00H
07H
XX100X01B 3) 6)
XX100001B 3) 7)
C5H
05H 6)
85H 7)
5)
A/D-
Converter
ADCON0 2)
ADCON1
ADDAT
ADST
ADDATH
A/D Converter Control Register 0
A/D Converter Control Register 1
A/D Converter Data Reg. (C505/C505C)
A/D Converter Start Reg. (C505/C505C)
A/D Converter High Byte Data Register
(C505A/C505CA)
D8H 1)
DCH
D9H
DAH
D9H
00X00000B 3)
01XXX000B 3)
00H
XXH 3)
00H
ADDATL A/D Converter Low Byte Data Register
(C505A/C505CA)
DAH
00XXXXXXB 3)
P1ANA 2) 4) Port 1 Analog Input Selection Register
90H 1)
FFH
Interrupt
System
IEN0 2)
IEN1 2)
IP0 2)
IP1
TCON 2)
T2CON 2)
SCON 2)
IRCON
Interrupt Enable Register 0
Interrupt Enable Register 1
Interrupt Priority Register 0
Interrupt Priority Register 1
Timer Control Register
Timer 2 Control Register
Serial Channel Control Register
Interrupt Request Control Register
A8H 1)
B8H 1)
A9H
B9H
88H 1)
C8H 1)
98H 1)
C0H 1)
00H
00H
00H
XX000000B 3)
00H
00X00000B
00H
00H
XRAM XPAGE Page Address Register for Extended on-chip 91H
00H
XRAM and CAN Controller
SYSCON2) System Control Register
B1H
XX100X01B 3) 6)
XX100001B 3) 7)
1) Bit-addressable special function registers
2) This special function register is listed repeatedly since some bits of it also belong to other functional blocks.
3) “X“ means that the value is undefined and the location is reserved
4) This SFR is a mapped SFR. For accessing this SFR, bit RMAP in SFR SYSCON must be set.
5)
6)
The content of this SFR varies with the actual step of the C505 (eg. 01H for the first step)
C505 / C505A only
7) C505C / C505CA only