比赛名单
SAKC505C-2RM
Siemens
Siemens AG Siemens
SAKC505C-2RM Datasheet PDF : 85 Pages
First Prev 21 22 23 24 25 26 27 28 29 30 Next Last
C505 / C505C
C505A / C505CA
Table 6
Contents of the CAN Registers in numeric order of their addresses
(C505C/C505CA only)
Addr. Register Content Bit 7
n=1-FH
1)
after
Reset 2)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
F700H
F701H
F702H
F704H
F705H
CR
SR
IR
BTR0
BTR1
F706H GMS0
F707H GMS1
F708H
F709H
F70AH
F70BH
UGML0
UGML1
LGML0
LGML1
F70CH
F70DH
F70EH
F70FH
UMLM0
UMLM1
LMLM0
LMLM1
F7n0H MCR0
F7n1H MCR1
01H
TEST CCE 0
0
EIE SIE IE
INIT
XXH BOFF EWRN –
RXOK TXOK LEC2 LEC1 LEC0
XXH
INTID
UUH
SJW
BRP
0UUU. 0
TSEG2
TSEG1
UUUUB
UUH
ID28-21
UUU1.
ID20-18
1
1
1
1
1
1111B
UUH
ID28-21
UUH
ID20-13
UUH
ID12-5
UUUU.
ID4-0
0
0
0
U000B
UUH
ID28-21
UUH
ID20-18
ID17-13
UUH
ID12-5
UUUU.
ID4-0
0
0
0
U000B
UUH
MSGVAL
TXIE
RXIE
INTPND
UUH
RMTPND
TXRQ
MSGLST
CPUUPD
NEWDAT
F7n2H UAR0 UUH
ID28-21
F7n3H UAR1 UUH
ID20-18
ID17-13
F7n4H LAR0 UUH
ID12-5
F7n5H LAR1
UUUU.
U000B
ID4-0
0
0
0
F7n6H MCFG
UUUU.
UU00B
DLC
DIR XTD 0
0
1) The notation “n“ (n= 1 to F) in the address definition defines the number of the related message object.