datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

TISP4070L3 查看數據表(PDF) - Power Innovations

零件编号
产品描述 (功能)
比赛名单
TISP4070L3 Datasheet PDF : 14 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
TISP4070L3BJ, TISP4350L3BJ
BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTORS
AUGUST 1999 — REVISED NOVEMBER 1999
IT Equipment
param eters
Connects A
to outside
cable
Yes
UL 1950 Third Edition
Telecommunication network connection
Clause 6.6 — Protection against overvoltage from power line crosses
Figure 18b — Overvoltage flowchart
Annex NAC (normative) — Power line crosses
No
Test 1.
600 V, 40 A,
1.5 s
No overvoltage
testing
Has
B
100 A2s
No
@ 600 V
†)
Yes
Has min. E
I
26 AW G
s u p p lied
No
Pass Test 1
cord
No
Test 5.
120 V, 25 A,
Yes
Yes
30 min or
open circuit
Has
C
1.3 A
d .c .
No
limiting ‡ )
Test 2. ¶ )
600 V, 7 A, 5 s
Test 3. # )
600 V, 2.2 A,
30 min or open circuit (3A)
Test 3A. # )
Yes 600 V, < 2.2 A, 30 min, no
open circuit
Test 4. # )
< Limiting voltage, < 2.2 A,
30 min, no open circuit, no
overvoltage protector
voltage limiting
Has
D
fire
No
enclosure
Pass 6.3.3 F
J
ground/line
separation
No
Pass test 5
No
Fail
§)
Yes
Yes
Has fire G
enclosure
and
Yes
spacings
No
Pass test 2 H
pass tests
3, 4
No
Yes
Pass
Yes
NOTES
† ) Overcurrent protector I2t must must be lower than any other equipment element which carries the same current.
‡ ) UL accepts that a fuse with a 1 A or less rating meets the 1.3 A criterion.
§ ) Pass for 120 V a.c. between telecommunication line and ground current < 10 mA.
¶ ) Test 2 not required if the equipment d.c. breaking is 1.3 A or less, see comment ‡ ).
# ) Tests 3 and 4 not required for equipment with less than 1000 m of outside cable.
Pass criteria
No cheesecloth charring
Insulation OK
wiring simulator (fuse) OK
I2t < 100 A2s @ 600 V a.c.
Test 1
Test 2
Test 3 Test 3A Test 4
Test 5
Figure 3. UL 1950 POWER CROSS FLOW CHART
PRODUCT INFORMATION