datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MAX221EEUE 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
比赛名单
MAX221EEUE Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
±15kV ESD-Protected, +5V, 1µA, Single RS-232
Transceiver with AutoShutdown
+2.7V
+0.3V
0
-0.3V
-2.7V
a)
TRANSMITTER ENABLED, INVALID HIGH
INDETERMINATE
AUTOSHUTDOWN, TRANSMITTER DISABLED,
1µA SUPPLY CURRENT, INVALID LOW
INDETERMINATE
TRANSMITTER ENABLED, INVALID HIGH
RECEIVER
INPUT
VOLTAGE
(V)
INVALID
REGION
VCC
INVALID
OUTPUT
(V)
0
tINVL
V+
VCC
0
V-
b)
tINVH
tWU
Figure 3. AutoShutdown Trip Levels
POWER-
MASTER SHDN LINE
MANAGEMENT
UNIT
0.1µF 1M
FORCEOFF FORCEON
MAX221E
Figure 4. AutoShutdown with Initial Turn-On to Wake Up a
Mouse or Another System
Software-Controlled Shutdown
For direct software control, use INVALID to indicate a
DTR or Ring Indicator signal. Connect FORCEOFF and
FORCEON together to disable AutoShutdown so the
line acts like a SHDN input.
±15kV ESD Protection
As with all Maxim devices, ESD-protection structures
are incorporated on all pins to protect against electro-
static discharges encountered during handling and
assembly. The driver output and receiver input of the
MAX221E have extra protection against static electrici-
ty. Maxim’s engineers have developed state-of-the-art
structures to protect these pins against ESD of ±15kV
without damage. The ESD structures withstand high
ESD in all states: normal operation, shutdown, and
powered down. After an ESD event, Maxim’s E versions
keep working without latchup, whereas competing
RS-232 products can latch and must be powered down
to remove latchup.
ESD protection can be tested in various ways; the trans-
mitter output and receiver input of the MAX221E are
characterized for protection to the following limits:
1) ±15kV using the Human Body Model
2) ±8kV using the Contact-Discharge Method
specified in IEC 1000-4-2
3) ±15kV using IEC 1000-4-2’s Air-Gap Method
ESD Test Conditions
ESD performance depends on a variety of conditions.
Contact Maxim for a reliability report that documents
test setup, test methodology, and test results.
Human Body Model
Figure 5a shows the Human Body Model, and Figure
5b shows the current waveform it generates when dis-
charged into a low impedance. This model consists of
a 100pF capacitor charged to the ESD voltage of inter-
est, which is then discharged into the test device
through a 1.5kresistor.
IEC 1000-4-2
The IEC 1000-4-2 standard covers ESD testing and
performance of finished equipment; it does not specifi-
cally refer to integrated circuits. The MAX221E helps
you design equipment that meets Level 4 (the highest
level) of IEC 1000-4-2, without the need for additional
ESD-protection components.
The major difference between tests done using the
Human Body Model and IEC 1000-4-2 (Figure 6) is
higher peak current in the IEC 1000-4-2 because series
resistance is lower in the IEC 1000-4-2 model. Hence,
_______________________________________________________________________________________ 7

Share Link: 