CF5760 series
Reset Function (optional seconds control function)
When AI/R goes active level for a reset, the motor output stops. When the reset is released, the first motor out-
put pulse occurs on the output pin opposite to that which had the last output pulse immediately before the reset.
AI/R
(Active Low)
O1
(Active High)
O2
(Active High)
tPW
tPW
tCY
tCY
tON
t +0
CY −125msec
Alarm Output
Alarm output waveform
AI/R
(Active High)
AO
(Active High)
*1
AON
(Active Low)
tON
fCY (Hz)
fPW(Hz)
*1: Opposite phase to AO.
fPW = alarm fundamental frequency
fCY = alarm modulation frequency
F Output Function
The AON pin may be replaced by the F pin which is used to output a 32kHz signal (unaffected by the reset
function).
SEIKO NPC CORPORATION —5