STM1061
Table 5. DC and AC Characteristics
Sym
Description
VCC
Operating Voltage
ICC
VCC Supply Current
IOUT
Output Current, N-channel
(VDS = 0.5V),
Reset asserted
Voltage Thresholds
VTH–
Detect Voltage
(see Table 9., page 18 for
detailed listing)
Test Condition(1)
VCC = 3.0V, No Load
VCC = 5.5V, No Load
VCC = 1.0V
VCC = 2.0V
VCC = 3.0V
VCC = 4.0V
VCC = 5.0V
VTH+ Release Voltage
VHYST Threshold Hysteresis
tPD
VCC to OUT Detect Delay
VCC falling from
(VTH– + 100mV) to
(VTH– – 100mV)
at 10mV/µs
tPR
VCC to OUT Release Delay
VCC rising from
(VTH+ – 100mV) to
(VTH+ + 100mV)
at 10mV/µs
Threshold Temperature
Coefficient
Note: 1. Valid for Ambient Operating Temperature: TA = 25°C.
Min
0.7
1.0
3.0
5.0
6.0
7.0
VTH– – 2%
0.02VTH–
Typ
Max
Unit
6.0
V
0.9
3.0
µA
1.1
3.6
µA
1.7
mA
14
mA
22
mA
26
mA
30
mA
VTH–
VTH– + 2% V
VTH– +
VHYST
V
0.05VTH– 0.08VTH–
V
25
µs
30
±100
200
µs
ppm/
oC
13/21