AD708
Parameter
OUTPUT VOLTAGE
OPEN-LOOP OUTPUT RESISTANCE
POWER SUPPLY
Quiescent Current
Power Consumption
Operating Range
Conditions
RLOAD ≥ 10 kΩ
RLOAD ≥ 2 kΩ
RLOAD ≥ 1 kΩ
TMIN to TMAX
VS = ±15 V
VS = ±3 V
AD708J/AD708A
AD708B
AD708S
Min1 Typ Max1 Min1 Typ Max1 Min1 Typ Max1 Unit
13.5 14
13.5 14.0
13.5 14
±V
12.5 13.0
12.5 13.0
12.5 13
±V
12.0 12.5
12.0 12.5
12.0 12.5
±V
12.0 13.0
12.0 13.0
12.0 13
±V
60
60
60
Ω
4.5 5.5
4.5 5.5
4.5 5.5 mA
135 165
135 165
135 165 mW
12 18
12 18
12 18 mW
±3
±18 ±3
±18 ±3
±18 V
1 All min and max specifications are guaranteed. Specifications in boldface are tested on all production units at final electrical test. Results from those tests are used to
calculate outgoing quality levels.
2 Input offset voltage specifications are guaranteed after five minutes of operation at TA = 25°C.
3 Matching is defined as the difference between parameters of the two amplifiers.
Rev. C | Page 4 of 16