datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MB40C338VPFV 查看數據表(PDF) - Fujitsu

零件编号
产品描述 (功能)
比赛名单
MB40C338VPFV Datasheet PDF : 19 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MB40C338V
s RECOMMENDED OPERATING CONDITIONS
Parameter
Symbol
Min.
Value
Typ.
Unit
Max.
AVDD, DVDD
3.00
3.30
3.60
V
Power supply voltage
PVDD
3.00
3.30
3.60
V
VESD
3.00
5.25
V
A/D converter input voltage
VADIN
VRB
VRT
V
Analog reference voltage: T
VRT
2.2
AVDD 0.6
V
Analog reference voltage : B
VRB
0.6
0.7
V
Analog reference voltage range
VRT VRB
1.0
1.5
1.8
V
Video AMP input voltage
VIN (P-P)
0.5
0.9
VP-P
Clamp input voltage
VCLP
0.6
VRB
1.7
V
Digital “H” level input voltage
VIHD
2.5
VESD
V
Digital “L” level input voltage
VILD
0
0.5
V
Digital “H” level output current
IOHD
400
µA
Digital “L” level output current
IOLD
1.6
mA
PLL counter
PC
100
4095
HSYNC input frequency range
fHSYNC
10
100
kHz
HHOLD set up time
tsHHOLD
20
ns
HHOLD hold time
thHHOLD
20
ns
Clamp pulse width
tWCLP
0.5
µs
CK clock pulse width
tWCKL, tWCKH
100
ns
DATA set up time
tsDATA
30
ns
DATA hold time
thDATA
30
ns
CS set up time
tsCS
50
ns
CS hold time
thCS
50
ns
CS “H” level hold time
tWCSH
100
ns
Operating temperature range
Ta
20
70
°C
WARNING: The recommended operating conditions are required in order to ensure the normal operation of the
semiconductor device. All of the device’s electrical characteristics are warranted when the device is
operated within these ranges.
Always use semiconductor devices within their recommended operating condition ranges. Operation
outside these ranges may adversely affect reliability and could result in device failure.
No warranty is made with respect to uses, operating conditions, or combinations not represented on
the data sheet. Users considering application outside the listed conditions are advised to contact their
FUJITSU representatives beforehand.
7

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]