datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

PBL38611-2 查看數據表(PDF) - Ericsson

零件编号
产品描述 (功能)
比赛名单
PBL38611-2 Datasheet PDF : 18 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
PBL 386 11/2
Maximum Ratings
Parameter
Temperature, Humidity
Storage temperature range
Operating temperature range
Operating junction temperature range, Note 1
Power supply, 0°C TAmb +70°C
VCC with respect to AGND
VEE with respect to AGND
VBat2 with respect to A/BGND
VBat with respect to BGND, continuous
VBat2 with respect to BGND, 10 ms
Power dissipation
Continuous power dissipation at TAmb +70 °C
Ground
Voltage between AGND and BGND
Relay Driver
Ring relay supply voltage
Ring relay current
Ring trip comparator
Input voltage
Input current
Digital inputs, outputs (C1, C2, C3, DET)
Input voltage
Output voltage (DET not active)
Output current (DET)
TIPX and RINGX terminals, 0°C < TAmb < +70°C, VBat = -50 V
TIPX or RINGX current
TIPX or RINGX voltage, continuous (referenced to AGND), Note 2
TIPX or RINGX, pulse < 10 ms, tRep > 10 s, Note 2
TIPX or RINGX, pulse < 1 µs, tRep > 10 s, Note 2
TIP or RING, pulse < 250 ns, tRep > 10 s, Note 3
Symbol
Min
TStg
-55
TAmb
-40
TJ
-40
Max
Unit
+150
°C
+110
°C
+140
°C
VCC
-0.4
6.5
V
VEE
VBat
0.4
V
VBat2
VBat
0.4
V
VBat
-75
0.4
V
VBat2
-80
0.4
V
PD
1.5
W
VG
-5
VCC
V
BGND +13 V
75 mA
VDT, VDR
VBat
VCC
V
IDT, IDR
-5
5
mA
VID
-0.4
VCC
V
VOD
-0.4
VCC
V
IOD
30
mA
ITIPX, IRINGX -110
+110
mA
VTA, VRA
VBat
2
V
VTA, VRA VBat - 20 5
V
VTA, VRA VBat - 40 10
V
VTA, VRA VBat - 70 15
V
Recommended Operating Condition
Parameter
Ambient temperature
VCC with respect to AGND
VEE with respect to AGND
VBat with respect to BGND
VBat2 with respect to BGND
Symbol
TAmb
VCC
VEE
VBat
VBat2
Min
0
4.75
VBat
-58
VBat
Max
Unit
+70
°C
5.25
V
-4.75
V
-10
V
-10
V
Notes
1. The circuit includes thermal protection. Operation above max. junction temperature may degrade device reliability.
2. A diode in series with the VBat input increases the permitted continuous voltage and pulse < 10 ms to -85 V.
A pulse 1µs is increased to the greater of |-70V| and |VBat -40V|.
3. RF1 and RF2 20 is also required. Pulse is supplied to TIP and RING outside RF1 and RF2.
2

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]