LT8301
OPERATION
The LT8301 is a simple to use micropower isolated flyback
converter housed in a 5-lead TSOT-23 package. The output
voltage is programmed with a single external resistor. By
integrating the loop compensation and soft-start inside, the
part further reduces the number of external components.
As shown in the Block Diagram, many of the blocks are
similar to those found in traditional switching regulators
including reference, regulators, oscillator, logic, current
amplifier, current comparator, driver, and power switch.
The novel sections include a flyback pulse sense circuit,
a sample-and-hold error amplifier, and a boundary mode
detector, as well as the additional logic for boundary
conduction mode, discontinuous conduction mode, and
low ripple Burst Mode operation.
Boundary Conduction Mode Operation
The LT8301 features boundary conduction mode operation
at heavy load, where the chip turns on the primary power
switch when the secondary current is zero. Boundary
conduction mode is a variable frequency, variable peak-
current switching scheme. The power switch turns on
and the transformer primary current increases until an
internally controlled peak current limit. After the power
switch turns off, the voltage on the SW pin rises to the
output voltage multiplied by the primary-to-secondary
transformer turns ratio plus the input voltage. When the
secondary current through the output diode falls to zero,
the SW pin voltage collapses and rings around VIN. A
boundary mode detector senses this event and turns the
power switch back on.
Boundary conduction mode returns the secondary current
to zero every cycle, so parasitic resistive voltage drops
do not cause load regulation errors. Boundary conduc-
tion mode also allows the use of smaller transformers
compared to continuous conduction mode and does not
exhibit sub-harmonic oscillation.
Discontinuous Conduction Mode Operation
As the load gets lighter, boundary conduction mode in-
creases the switching frequency and decreases the switch
peak current at the same ratio. Running at a higher switching
frequency up to several MHz increases switching and gate
charge losses. To avoid this scenario, the LT8301 has an
additional internal oscillator, which clamps the maximum
switching frequency to be less than 430kHz (typ). Once
the switching frequency hits the internal frequency clamp,
the part starts to delay the switch turn-on and operates in
discontinuous conduction mode.
Low Ripple Burst Mode Operation
Unlike traditional flyback converters, the LT8301 has to
turn on and off at least for a minimum amount of time
and with a minimum frequency to allow accurate sampling
of the output voltage. The inherent minimum switch cur-
rent limit and minimum switch-off time are necessary to
guarantee the correct operation of specific applications.
As the load gets very light, the LT8301 starts to fold back
the switching frequency while keeping the minimum switch
current limit. So the load current is able to decrease while
still allowing minimum switch-off time for the sample-
and-hold error amplifier. Meanwhile, the part switches
between sleep mode and active mode, thereby reducing the
effective quiescent current to improve light load efficiency.
In this condition, the LT8301 operates in low ripple Burst
Mode. The 10kHz (typ) minimum switching frequency
determines how often the output voltage is sampled and
also the minimum load requirement.
8301f
8
For more information www.linear.com/LT8301