datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

M52347FP 查看數據表(PDF) - MITSUBISHI ELECTRIC

零件编号
产品描述 (功能)
比赛名单
M52347FP
Mitsubishi
MITSUBISHI ELECTRIC  Mitsubishi
M52347FP Datasheet PDF : 13 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MITSUBISHI ICs (Monitor)
M52347SP/FP
SYNC SIGNAL PROCESSOR
ELECTRICAL CHARACTERISTICS (cont.)
Symbol
Parameter
Relay
condition
TP
condition
In
put
4 6 8 16 3 10 pin
15 OH
Pin 15 output
Hi level
0V
4
1 1 2 1 2.5V 5V
5V
6
15 OL
Pin 15 output
Low level
0V
4
1 1 2 1 2.5V 5V
5V
6
17 OH
Pin 17 output
Hi level
0V
4
1 1 2 1 2.5V 5V
5V
6
17 OL
Pin 17 output
Hi level
0V
4
1 1 2 1 2.5V 5V
5V
6
Out
Input condition put
pin
50kHz
1µS 0.6VP-P
50kHz
15
1µS 2VP-P
50kHz
1µS 0.6VP-P
50kHz
15
1µS 2VP-P
1µS
50kHz
0.6V P-P
1µS 50kHz
17
2V P-P
50kHz
1µS 0.6VP-P
50kHz
17
1µS 2VP-P
Output waveform
V Meas
V Meas
V Meas
V Meas
13 OH
Pin 13 output
Hi level
0V
2 2 1 1 2.5V 5V 8
5V
50kHz
1µS 2VP-P
13
V Meas
Note
Limits
Unit
Min. Typ. Max.
4.0 5.0 5.0 V
0 0.25 0.5 V
4.0 5.0 5.0 V
0 0.25 0.5 V
4.0 5.0 5.0 V
13 OL
12 OH
12 OL
SS-NV
SS-LV
V3H
V3L
V10
Pin 13 output
Low level
0V
2 2 1 1 2.5V 5V 8
5V
50kHz
1µS 2VP-P
13
V Meas
Pin 12 output
Hi level
0V
4
1 1 2 1 2.5V 5V
5V
6
Pin 12 output
Low level
0V
4
1 1 2 1 2.5V 5V
5V
6
Sync-Sep
Sync input
0V
signa Max. 1 2 2 1 2.5V 5V 4
noise ampli-
5V
tude voltage
Sync-Sep
Sync input
0V
signal
1 2 2 1 2.5V 5V 4
Min. ampli-
5V
tude voltage
50kHz
1µS 0.6VP-P
50kHz
12
1µS 2VP-P
50kHz
1µS 0.6VP-P
50kHz
12
1µS 2VP-P
V Meas
V Meas
14
50kHz
No pulse must be
1µS 0.05VP-P 15 output.
17
50kHz
1µS 0.2VP-P
50kHz
14
No pulse must be
17 output in this por-
tion.
CLAMP SW
Threshold 2 1 2 1
voltage H
DC voltage must 14
be applied.
3
17
5V
6
1µS 50kHz
15
2VP-P
CLAMP SW
Threshold
voltage H
Variable
2121
DC voltage must 14
be applied.
3
17
5V
6
1µS
50kHz
2VP-P
15
V TIME
GATE SW
Threshold
voltageVari-
able
2
1
1
1
0V
5V
50kHz
6
1µS 2VP-P
50kHz
14
8
1µS 2VP-P
10 DC voltage must 15
be applied.
0 0.25 0.5 V
4.0 5.0 5.0 V
0 0.25 0.5 V
Must not oper-
ate when input
amplitude is
0.05 VP-P or
-
less. (Pseudo
noise signal)
- 0.05 VP-P
Must operate
when the input
amplitude is
0.2 -
0.2 VP-P or
more.
- VP-P
Checking output
pulse for output
with a voltage of
5 VDC applied,
decrease the DC
voltage and then
2.8 3.1 3.4
V
measure the volt-
age when the
output pulse is
not output.
Checking output
pulse for output
with a voltage of
0 VDC applied,
increase the DC
voltage and then
1.0 1.3 1.6
V
measure the volt-
age when the
output pulse is
not output.
Checking output
pulse for output
with a voltage of
5 VDC applied,
decrease the DC
voltage and then
2.0 2.5 3.0
V
measure the volt-
age when the
output pulse
becomes narrow.
3

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]