datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MX10EXAQC 查看數據表(PDF) - Macronix International

零件编号
产品描述 (功能)
比赛名单
MX10EXAQC Datasheet PDF : 55 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
MX10EXA
In-Application Programming Method
Several Application Program Interface (API) calls are available for use by an application program to permit selective
erasing and programming of FLASH sectors. All calls are made through a common interface, PGM_MTP. The pro-
gramming functions are selected by setting up the microcontroller's registers before making a call to PGM_MTP at
FFFOH. Results are returned in the registers. The API calls are shown in Table 2.
Table 2. API calls
API CALL
PROGRAM DATA BYTE
ERASE BLOCK
ERASE BPC and
STATUS BYTE
PROGRAM SECURITY
BIT
PROGRAM STATUS
BYTE
PROGRAM BPC HIGH
BYTE
PARAMETER
Input Parameters:
R0H = 02h or 92h
R6 = address of byte to program
R4L = byte to program
Return Parameter
R4L = 00 if pass, non-zero if fail
Input Parameters:
R0H = 01h or 93h
R6H = block number in bits 7:5, bits 4:0 = "0"
block 0 : R6H = 00h
block 1 : R6H = 20h
block 2 : R6H = 40h
block 3 : R6H = 80h
block 4 : R6H = C0h
REL = 00h
Return Parameter
R4L = 00 if pass, non-zero if fail
Input Parameters:
ROH =04h
Return Parameter
R4L =00 if pass, non-zero if fail
Input Parameters:
R0H = 05h
R6H = 00h
R6L = 00h - security bit # 1 (inhibit writing to FLASH)
0lh - security bit # 2 (inhibit FLASH verify)
02h - security bit # 3 (disable external memory)
Return Parameter:none
Input Parameters:
R0H = 60h
R6H = 00h
R6L = 00H- program status byte
R4L = status byte
Return Parameter
R4L = 00 if pass, non-zero if fail
Note : only two bits of status byte may be programmed at one time
Input Parameters:
R0H = 06h
R6H = 00h
R6L = 0lh - program BPC
R4L = BPC[15:8] (BPC[7:0] unchanged)
Return Parameter
R4L = 00 if pass, non-zero if fail
Note : only two bits of BPC [15:8] may be programmed at one time
P/N:PM0625 Specifications subject to change without notice, contact your sales representatives for the most update information. REV. 1.0, JUL. 01, 2005
18

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]