0.1GHz to 2.5GHz, 75dB Logarithmic
Detector/Controller
AC ELECTRICAL CHARACTERISTICS (continued)
(MAX2015 Typical Application Circuit (Figure 1), VS = +3.3V, fRF = 100MHz to 2500MHz, R1 = 0, R4 = 0, RL = 10k, TA = -40°C
to +85°C, unless otherwise noted. Typical values are at TA = +25°C, unless otherwise noted.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX UNITS
Intercept
Typical Intercept Variation
RSSI MODE2.5GHz
RF Input Power Range
±3dB Dynamic Range
Range Center
(Note 5)
TA = -40°C to +85°C
(Note 2)
TA = -40°C to +85°C (Note 3)
-83
0.03
-45 to -5
40
-25
dBm
dBm/°C
dBm
dB
dBm
Temp Sensitivity when TA > +25°C
TA = +25°C to +85°C,
PIN = -25dBm
-0.0083
dB/°C
Temp Sensitivity when TA < +25°C
Slope
Typical Slope Variation
Intercept
Typical Intercept Variation
TA = -40°C to +25°C,
PIN = -25dBm
(Note 4)
TA = -40°C to +85°C
(Note 5)
TA = -40°C to +85°C
-0.0083
16.8
-8
-81
0.03
dB/°C
mV/dB
µV/°C
dBm
dBm/°C
Note 1: The MAX2015 is 100% production tested at TA = +25°C and is guaranteed by design for TA = -40°C to +85°C, as specified.
Note 2: Typical minimum and maximum range of the detector at the stated frequency.
Note 3: Dynamic range refers to the range over which the error remains within the stated bounds. The error is calculated at -40°C
and +85°C, relative to the curve at +25°C.
Note 4: The slope is the variation of the output voltage per change in input power. It is calculated by fitting a root-mean-square
(RMS) straight line to the data indicated by RF input power range.
Note 5: The intercept is an extrapolated value that corresponds to the output power for which the output voltage is zero.
It is calculated by fitting an RMS straight line to the data.