datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

AD8159 查看數據表(PDF) - Analog Devices

零件编号
产品描述 (功能)
比赛名单
AD8159
ADI
Analog Devices ADI
AD8159 Datasheet PDF : 24 Pages
First Prev 21 22 23 24
AC Coupling
In general, more VTTO supply headroom is required with ac-
coupled outputs. When the outputs are ac-coupled, the average
single-ended current does not see the far end 50 Ω termination
because the capacitor acts as a dc block. For example, with
PE = 0, the single-ended output current alternates from 0 mA
to 16 mA, or 8 mA on average. This 8 mA current flows entirely
through the on-chip 50 Ω termination resistor due to the dc
block.
The single-ended output voltage has an average value of
VTTO − 8 mA × 50 Ω = VTTO − 400 mV
For appropriate data patterns,1 the capacitor acts as a short and
the voltage swing is 400 mV p-p, identical to the dc-coupled case.
The low output voltage is, therefore,
VTTO − 400 mV − 200 mV = VTTO − 600 mV
1AC coupling requires that the signal pattern have no long term dc
component. Codes such as 8b/10b, for example, ensure that the data
pattern is benign in an ac-coupled link.
AD8159
The lowest acceptable value for VTTO is
VCC − 1.6 V + 0.6 V = VCC − 1.0 V
The same exercise can be repeated for other pre-emphasis
settings.
Output Compliance Table
To simplify the task of interfacing to the AD8159 output,
Table 13 is useful as a quick-reference. It provides the minimum
and maximum values for output termination voltage for both
ac and dc coupling. The values in the table are valid for any pre-
emphasis setting.
Table 13. Output Compliance
AC-Coupled
Minimum Maximum
(V)
(V)
VTTO VCC – 0.5
VCC + 0.6
VTTOI VCC – 0.4
VCC + 0.6
DC-Coupled
Minimum Maximum
(V)
(V)
VCC – 0.9
VCC + 0.6
VCC – 0.8
VCC + 0.6
Rev. A | Page 21 of 24