APW7067N
Function Description
Power-On-Reset (POR)
The Power-On-Reset (POR) function of APW7067N
continually monitors the input supply voltage (V ),
CC12
ensures the supply voltage exceed its rising POR
threshold voltage. The POR function initiates soft-start
interval operation while VCC12 voltage exceeds its POR
threshold and inhibits operation under disabled status.
Soft-Start
Figure 1. shows the soft-start interval. When VCC12 reaches
the rising POR threshold voltage, the internal reference
voltage is controlled to follow a voltage proportional to the
soft-start voltage. The soft-start interval is variable by the
oscillator frequency. The formulation is given by:
TSS = ∆(t2 t1) = 1 ×1280
FOSC
Figure 2. shows more detail of the FB and FBL voltage
ramps. The FB and FBL voltage soft-start ramps are
formed with many small steps of voltage. The voltage of
one step is about 20mV in VFB and VFBL, and the period of
one step is about 32/FOSC. This method provides a
controlled voltage rise and prevents the large peak
current to charge the output capacitors. The FB voltage
compares the FBL voltage to shift to an earlier time the
establishment as Figure2. The voltage estabilishment
time difference for VFB and VFBL is variable by the
oscillator. The formulation is given by:
(t4 t3) = 1 × 320 = 1 × TSS
FOSC
4
Voltage (V)
POR
VCC12
VOUT1
VOUT2
t0
t1
t2
Time
Figure 1. Soft-Start Interval
Voltage(V)
VFB
20mV
32/FOSC
VFBL
32/FOSC
20mV
t3
t4
Time
Figure 2. The Controlled Stepped FB and
FBL Voltage during Soft-Start
Over-Current Protection
The over-current protection monitors the output current by
using the voltage drop across the lower MOSFET’s
R and this voltage drop will be compared with the
DS(ON)
internal 0.25V reference voltage. When the voltage drop
across the lower MOSFET’s RDS(ON) is larger than 0.25V, an
over-current condition is detected, the controller will
shutdown the IC directly, and latch the converter's output.
The threshold of the over current limit is given by:
( ) ILIMIT
=
VOCP (0.25V)
RDS(ON) Low _ Side
For the over-current is never occurred in the normal
operating load range; the variation of all parameters in
the above equation should be determined.
- The MOSFET’s RDS(ON) is varied by temperature and
gate to source voltage, the user should determine
the maximum RDS(ON) in manufacture’s datasheet.
- The minimum VOCP should be used in the above
equation.
- Note that the ILIMIT is the current flow through the lower
MOSFET; I must be greater than maximum output
LIMIT
current add the half of inductor ripple current.
Under Voltage Protection
The FB and FBL pin are monitored during converter op-
eration by their own Under Voltage (UV) comparator. If
the FB or FBL voltage drop below 50% of the refer-
ence voltage (50% of 0.8V = 0.4V), a fault signal is inter-
nally generated, and the device turns off both high-side