datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MAX710 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
比赛名单
MAX710 Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MAX710/MAX711
3.3V/5V or Adjustable,
Step-Up/Down DC-DC Converters
ABSOLUTE MAXIMUM RATINGS
PS, LX, OUT to GND............................................-0.3V to +11.5V
ILIM, SHDN, STBY, FB, 3/5, N/E, LBO,
LBI-, LBI+, REF to GND ...........................-0.3V to (VPS + 0.3V)
PGND to GND .......................................................-0.3V to +0.3V
REF Short Circuit to GND ...........................................Continuous
IOUT ...................................................................................700mA
Continuous Power Dissipation (TA = +70°C)
SO (derate 8.70mW/°C above +70°C) ..........................696mW
Operating Temperature Range ...........................-40°C to +85°C
Storage Temperature Range .............................-65°C to +160°C
Junction Temperature ......................................................+150°C
Lead Temperature (soldering, 10sec) .............................+300°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(VPS = 5.6V, STBY = PS, CREF = 0.1µF, COUT = 4.7µF, TA = -40°C to +85°C, unless otherwise noted. Typical values are at
TA = +25°C.) (Note 1)
PARAMETER
Input Voltage
CONDITIONS
N/E = PS
N/E = GND (Note 2)
MIN TYP MAX UNITS
1.8
11.0
V
1.8
7.0
Full Load Start-Up Voltage
0.9
V
Output Voltage (MAX710)
Output Voltage-Adjustment Range
Output Voltage Load Regulation
Output Voltage Line Regulation
3/5 = low,
IOUT = 0 to 250mA
3/5 = high, IOUT = 0 to
250mA, VPS = 4.7V
TA = 0°C to +85°C
4.8
5.0
5.2
TA = -40°C to +85°C 4.6
5.0
5.3
V
TA = 0°C to +85°C
3.17
3.3
3.43
TA = -40°C to +85°C 3.05
3.3
3.55
MAX711
FB
5.5
V
0 < IOUT < 250mA, STBY = PS
0.5
%
STBY = PS, 1.8V to 5V
0.3
%/V
Quiescent Current
Standby Quiescent Current
VSTBY = VSHDN = logic high, current measured
into PS pin; ILOAD = 0
VSTBY = 0V
100
140
µA
7
16
µA
Shutdown Quiescent Current
VSHDN = 0V
0.1
5
µA
Reference Voltage
Standby Output Current
TA = 0°C to +85°C, IREF = 0
TA = -40°C to +85°C, IREF = 0
VSTBY = 0V, linear regulator
1.24 1.28 1.31
V
1.23 1.28 1.32
10
mA
FB Voltage
MAX711, OUT = FB
TA = 0°C to +85°C
1.20 1.25 1.29
mV
TA = -40°C to +85°C 1.18 1.25 1.31
Load Regulation
MAX711, OUT = FB
0mA ILOAD
250mA
0.1
1
%
FB Input Current
FB = 1.25V
1
50
nA
LX On-Resistance
LX Leakage Current
LX Current Limit
VPS = 5.6V
MAX710, VPS = 3.7V
MAX711, VPS = 2.7V
VLX = 5.6V
ILIM = PS
ILIM = GND
0.2
0.6
0.3
0.9
0.6
1.2
0.1
1
µA
0.5
0.8
1.3
A
1.1
1.5
1.95
2
Maxim Integrated

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]